Thermo Scientific™

STD5000 and STD6000 Current-to-Pressure (I/P) Transducers

Catalog number: 115052
Thermo Scientific™

STD5000 and STD6000 Current-to-Pressure (I/P) Transducers

Catalog number: 115052
Ensure reliable signal conversion in the most demanding industrial environments with Thermo Scientific™ STD5000 and STD6000 Current-to-Pressure (I/P) Transducers. Setting the standard in the industry for electronic input signal conversion, these transducers ensure accuracy, reliability and ease-of-use to facilitate operations and increase productivity.
 
Catalog Number
115052
Unit Size
Each
Description
STD5000 and STD6000 Current-to-Pressure (I/P) Transducers
Price (USD)
Full specifications
Air Consumption0.04 SCFM steady state average (0.06 SCFM maximum)
Air SupplyClean, dry and oil-free instrument air
ConnectionsSupply port; 0.25 in. NPTF (1X); Pneumatic Output Port: 0.25 in. NPTF (2X); Electrical: 0.5 in. NPTF conduit (2X); terminals 12 to 22 AWG wire
Deadband0.02% of span
DescriptionSTD5000 and STD6000 Current-to-Pressure (I/P) Transducers
EMI/RFILess than +1% effect on zero/span (26 to 1000MHz at 30V/m) when installed per product installation guidelines
EnclosureCast/machined aluminum with powder-coated epoxy
Failure ModeMechanically direct (i.e., if the input current drops below 3.7mA DC, the output will drop to 1 to 2psig regardless of direct or reverse mode selection)
Frequency Response-3dB at 5Hz (per ISA-S26.4.3.1 Configuration A)
Loop Load3.8VDC + 5ohm (195ohm load at 20mA)
Operating ModesField selectable direct, reverse and/or split range; see notes in model number description
Output CapacityStandard: 4.0 SCFM (supply and exhaust characteristics are balanced to within ±10%); High Pressure: 4 to 8 SCFM possible (dependent on air supply and tubing size)
Repeatability0.05% of span
Stability0.5% of span/6 months
Temperature EffectRange of 18° to 66°C (0° to 150°F): ±0.02%/°F of span; Range -40° to +66°C (-40° to +150°F): ±0.04%/°F of span
Vibration Effect<0.25% from 1 to 200Hz/1g
Weight (English)2.5 lb.
Weight (Metric)1.13kg
Item DescriptionNEMA 4X and IP65 enclosure
Certifications/ComplianceCE marked, ATEX, CSA/US
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
115052Full specifications
EachSTD5000 and STD6000 Current-to-Pressure (I/P) TransducersRequest A Quote
Air Consumption0.04 SCFM steady state average (0.06 SCFM maximum)
Air SupplyClean, dry and oil-free instrument air
ConnectionsSupply port; 0.25 in. NPTF (1X); Pneumatic Output Port: 0.25 in. NPTF (2X); Electrical: 0.5 in. NPTF conduit (2X); terminals 12 to 22 AWG wire
Deadband0.02% of span
DescriptionSTD5000 and STD6000 Current-to-Pressure (I/P) Transducers
EMI/RFILess than +1% effect on zero/span (26 to 1000MHz at 30V/m) when installed per product installation guidelines
EnclosureCast/machined aluminum with powder-coated epoxy
Failure ModeMechanically direct (i.e., if the input current drops below 3.7mA DC, the output will drop to 1 to 2psig regardless of direct or reverse mode selection)
Frequency Response-3dB at 5Hz (per ISA-S26.4.3.1 Configuration A)
Loop Load3.8VDC + 5ohm (195ohm load at 20mA)
Operating ModesField selectable direct, reverse and/or split range; see notes in model number description
Output CapacityStandard: 4.0 SCFM (supply and exhaust characteristics are balanced to within ±10%); High Pressure: 4 to 8 SCFM possible (dependent on air supply and tubing size)
Repeatability0.05% of span
Stability0.5% of span/6 months
Temperature EffectRange of 18° to 66°C (0° to 150°F): ±0.02%/°F of span; Range -40° to +66°C (-40° to +150°F): ±0.04%/°F of span
Vibration Effect<0.25% from 1 to 200Hz/1g
Weight (English)2.5 lb.
Weight (Metric)1.13kg
Item DescriptionNEMA 4X and IP65 enclosure
Certifications/ComplianceCE marked, ATEX, CSA/US
Unit SizeEach
Showing 1 of 1
Innovative, Field-Proven Design and Superior Technology:
  • Accurate, repeatable performance minimizes maintenance and increases process optimization
  • Field-proven E-Pi technology is unaffected by vibration, shock or mounting position
  • Intrinsically safe or explosion-proof models are available
Features:
  • Accuracies of ±0.15% to ±0.25% of span
  • High supply pressure ranges of 35 PSIG to 100 PSIG available with selected output ranges
  • Operating temperature range of -40 to +66°C (-40 to +150°F)
  • Rugged NEMA 4X and IP65 enclosure
  • Field selectable direct and reverse modes

Figures