3130 Genetic Analyzer (factory refurbished)

Catalog number: 3130XLR

Applied Biosystems™  Related applications: DNA Sequencing | Fragment Analysis | Genotyping & Genomic Profiling | Sanger Sequencing

Error loading your content!

  Catalog number
Select a plan
Unit size
Price ({{currency}}) Qty
{{product.sku}} {{product.sku}}
also known as {{product.formattedSku}} 
{{product.availability.message}}
Pro add-ons

Your on-site stock

›› {{supplyCenter.scName}}({{scProduct.stockOnHand}} In stock)
›› {{supplyCenter.scName}}(Out of stock)
›› {{supplyCenter.scName}}
This item is not currently available on-site. Depending on your Supply Center settings you may be able to add the item to cart above else use the Order Non-Stocked Items' tab on the Supply Center home page.
Back to top

Description

With the Applied Biosystems 3130 Genetic Analyzer, you get the sophisticated automation and superior performance of the 3130 system, at acquisition and operating costs tailored to a growing research lab. This instrument is refurbished by the original manufacturer to meet both manufacturing and product specifications. This system includes the refurbished instrument, new Windows computer, Data Collection software, choice of one analysis software package, installation by an Applied Biosystems “5-Step Certified" Field Service Engineer, chemistry kit, training, new parts and a one year warranty. Availability may be limited.

• Run a wide variety of sequencing and fragment analysis applications including microsatellite analysis, AFLP, LOH, SNP validation, and SNP screening.
• Reduce maintenance time by eliminating manual syringe washing and filling with automated polymer delivery.
• Increase your data quality for sequencing and fragment analysis applications – longer read length, and higher resolution with shorter run times.
• Increase laboratory productivity and turnaround time by processing 96- or 384-well plates with a four-capillary array.

Perform a Wide Range of Applications
The Applied Biosystems 3130 Genetic Analyzer is more than just a DNA sequencer. You can run a wide variety of sequencing and fragment analysis applications including microsatellite analysis, AFLP, LOH, SNP validation, and SNP screening – as well as de novo sequencing and resequencing (mutational profiling). The full range of applications can be run on a single polymer and capillary array meaning you can run mixed applications on one plate. The software even includes tools to assist with regulatory and compliance requirements (In the United States, this assists with FDA 21CFR part 11).

Easy to Use
Reduce maintenance time by eliminating manual syringe washing and filling with the new automated polymer delivery system. No more handling of polymer syringes for set up and maintenance. Samples are automatically injected into the four-capillary arrays, and – unlike slab-gel systems – only minimal amounts of DNA are required for accurate analysis. Seamlessly switch between sequencing and fragment analysis runs, even in the same plate with the expanded one-polymer, one-array functionality for both sequencing and fragment analysis applications.

Superior Data Quality
Simply set up your sample and then sit back and watch as the analyzer's ultra-rapid sequencing gives you high-quality data (with Length of Read longer than 500 bp) in less than 35 minutes. Achieve accurate read lengths of 1,000 base pairs (bp) or longer in a single sequencing reaction using the 80 cm capillary array and the 3130 POP-7™ polymer.

Ideal for Growing Labs
The flexible, four-capillary 3130 system gives you all the advanced automation and superior performance of Applied Biosystems 3130xl platform, at acquisition and operating costs tailored to a growing research lab. And as your throughput needs increase, you can easily upgrade the system to 16 capillaries. It is the perfect way to get the capacity and savings you need today – without limiting your growth options. Researchers who own an ABI PRISM® 3100-Avant or 3100 Genetic Analyzer can upgrade to the new Applied Biosystems 3130 or 3130xl Genetic Analyzer.

3130 and 3130xl instruments are CE marked and compliant with the specifications and requirements as set in the EMC directive 89⁄336⁄EEC and the Low Voltage directive 73⁄23⁄EEC.

For Research Use Only. Not for use in diagnostics procedures.
For Research Use Only. Not for use in diagnostic procedures.

Specifications

Analysis Software: GeneMapper® Software
Capillary Length: 22cm, 36cm, 50 cm, 80cm
Compatible Polymers: POP-4, POP-6, POP-7
Compatible Products: BigDye®Terminator Kits, dRhodamine Dye Terminator Kit
Current Limit: 15 A
Dimensions: Depth: 55cm, Height: 81cm, Width (open): 149cm
For Use With (Equipment): 3130 Genetic Analyzer
Format: 384-well plate, 96-well plate
Number of Capillaries: 16 Capillaries
Operating Environment: Humidity: 20%-80%, Temperature: 15°C-30°C
Operating System: Microsoft Windows 7
Performance: 98.5% basecalling accuracy
Plan Duration: 1 Year Warranty
Polymer Consumption: Up to 960 samples per 7000µl Bottle
Product Line: Applied Biosystems™
Product Size: 1 instrument
Read Length: Up to 950bp
Sample Volume: > 10µL
Throughput: 121,600 bases/24hr (Long Read Sequencing), 17,280 genotypes/24hr (4-dye DNA sizing), 23,040 genotypes/24hr (5-dye DNA sizing), 328,000 bases/24hr (Ultra Rapid Sequencing)
Voltage Limit: 200-220V or 230-240V
Weight: 130 kg

Contents & storage

This product includes the refurbished instrument, a new computer, software, choice of one analysis software package, chemistry kit, and new parts.

Documents

Manuals & protocols