Thermo Scientific™

Model 42i-Y NOY Analyzer

Catalog number: 42IY
Thermo Scientific™

Model 42i-Y NOY Analyzer

Catalog number: 42IY
Measure the amount of nitrogen oxides in the air from sub-ppb levels up to 1000 ppb using chemiluminescence with the Thermo Scientific™ Model 42i-Y NOY Analyzer.The Model 42i-Y is a single chamber, single photomultiplier tube design that measures NOY which includes most oxides of nitrogen with the exception of NH3 and N2O.

The 42i-Y complies with all USEPA NCore Network requirements for the measurement of NOy.
 
Catalog Number
42IY
Unit Size
Each
Description
42i-Y NOy Analyzer
Price (EUR)
Full specifications
Detectable AnalytesNOy
Flow Rate1 L/min.
Inputs16 Digital Inputs (Standard), 8 0 to 10 VDC Analog Inputs (Optional)
Linearity±1% full scale
Span Drift±1% full scale
Temperature (English) Operating32°F to 113°F
Temperature (Metric) Operating0°C to 45°C
Zero Noise<25 ppt RMS
Certifications/ComplianceETL, CSA, UL, CE, UKCA
Depth (English)23 in.
Depth (Metric)584 mm
Description42i-Y NOy Analyzer
Detection Limit<50 ppt (120 second averaging time)
Height (English)8.62 in.
Height (Metric)219 mm
Measurement Range0 to 5, 10, 20, 50, 100, 200 ppb and 0 to 10, 20, 50, 100, 200, 500, 1000, and 2000 mg/m3 to 0 to 10, 20, 50, 100, 200 μg/m3
OutputsSelectable Voltage, RS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard); 0 to 20 or 4 to 20mA Isolated Current Outout (optional)
Voltage100/115/220/240 V
Weight (English)55 lb.
Weight (Metric)25 kg
Width (English)16.75 in.
Width (Metric)425 mm
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeDescriptionPrice (EUR)
42IYFull specifications
Each42i-Y NOy AnalyzerRequest A Quote
Detectable AnalytesNOy
Flow Rate1 L/min.
Inputs16 Digital Inputs (Standard), 8 0 to 10 VDC Analog Inputs (Optional)
Linearity±1% full scale
Span Drift±1% full scale
Temperature (English) Operating32°F to 113°F
Temperature (Metric) Operating0°C to 45°C
Zero Noise<25 ppt RMS
Certifications/ComplianceETL, CSA, UL, CE, UKCA
Depth (English)23 in.
Depth (Metric)584 mm
Description42i-Y NOy Analyzer
Detection Limit<50 ppt (120 second averaging time)
Height (English)8.62 in.
Height (Metric)219 mm
Measurement Range0 to 5, 10, 20, 50, 100, 200 ppb and 0 to 10, 20, 50, 100, 200, 500, 1000, and 2000 mg/m3 to 0 to 10, 20, 50, 100, 200 μg/m3
OutputsSelectable Voltage, RS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard); 0 to 20 or 4 to 20mA Isolated Current Outout (optional)
Voltage100/115/220/240 V
Weight (English)55 lb.
Weight (Metric)25 kg
Width (English)16.75 in.
Width (Metric)425 mm
Unit SizeEach
Showing 1 of 1

Key Features:

  • Standard dual range and auto ranges
  • 10-second response time
  • Temperature and pressure correction
  • User selectable alarm levels for concentration

iSeries Advantage:

  • Ethernet connectivity for efficient remote access
  • Enhanced user interface with one button programming and large display screen
  • Flash memory for increased data storage and user downloadable software
  • Enhanced electronics design optimizes product commonality
  • Improved layout for easier accessibility to components

Ordering Information:

Voltage options:

A = 115 Vac 60 Hz

B = 220/240 Vac 50Hz

C = 220 Vac 60 Hz

D = 115 Vac 50 Hz

J = 100 Vac 50/60 Hz

Internal zero / span:

N = No zero / span assembly (standard)

Z = Internal zero span assembly

Converter options:

M = Molybdenum (standard)

Sample handling:

S = Standard plumbing (standard)

Ozone handling:

D = Drierite scrubber (standard)

P = Permeation dryer

Optional I/O:

A = None (standard)

C = I/O expansion board

Mounting Hardware:

A = Bench mounting (standard)

B = Ears and handles, EIA