Description

POP-7™ Polymer is a separation matrix for performing DNA sequencing and fragment analysis on the Applied Biosystems 3130 and the Applied Biosystems 3130xl Genetic Analyzers. Usage per bottle: Up to 250 samples.

POP-7™ Polymer is:
• Easy to Use: Pre-formulated, which not only saves time but also saves reproducibility by ensuring consistent formulation
• Robust Formulation: Formulated for sequencing and fragment analysis applications.
• Replenishable: Allow capillaries to be used multiple times

Reproducible Results
POP-7™ polymer dynamically coats the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP-7™ Polymer is specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time.

For the ABI PRISM® 3700 DNA Analyzer POP-7™ polymer is the separation matrix of choice for high-throughput DNA sequencing.

Used With
310 Running Buffer, 10X , 3130 Genetic Analyzer, 3130⁄3100-Avant™ Genetic Analyzer Capillary Array, 22 cm, 3130⁄3100-Avant™ Genetic Analyzer Capillary Array, 36 cm, 3130⁄3100-Avant™ Genetic Analyzer Capillary Array, 50 cm, 3130⁄3100-Avant™ Genetic Analyzer Capillary Array, 80 cm, 3130xl⁄3100 Genetic Analyzer Capillary Array, 22 cm, 3130xl⁄3100 Genetic Analyzer Capillary Array, 36 cm, 3130xl⁄3100 Genetic Analyzer Capillary Array, 50 cm, 3130xl⁄3100 Genetic Analyzer Capillary Array, 80 cm, 96-Well Plate Septa, BigDye® Terminator v1.1 Cycle Sequencing Kit, BigDye® Terminator v3.1 Cycle Sequencing Kit, BigDye® Terminator v3.1 Cycle Sequencing Kit, GeneScan™ 500 LIZ™ Size Standard, GeneScan™ 500 ROX™ Size Standard, Hi-Di™ Formamide, MicroAmp® Optical 96-Well Reaction Plate, methylSEQr™ Bisulfite Conversion Kit.

For Research Use Only. Not for use in diagnostics procedures.
For Research Use Only. Not for use in diagnostic procedures.

Specifications

Accuracy: 98.5% up to 950 bases (for 80 cm capillary), 98.5% up to 500 bases (for 36 cm capillary)
For Use With (Application): Fragment Analysis, Sequencing
For Use With (Equipment): 3130xl Genetic Analyzer, 3130 Genetic Analyzer
On Instrument Life Usage: Stability on instrument 7 days, Up to 250 samples/3.5 ml
Product Line: POP-7™
Recommended Applications: Standard Sequencing, Fragment Analysis (Denaturing)
Additional Information: 98.5% upto 500 bases (for 36cm capillary), 98.5% upto 950 bases (for 80cm capillary) accuracy, Stability on instrument 7 days, Up to 250 samples/3.5mL