Thermo Scientific™

Orion™ Sodium Electrodes

Catalog number: 8611BNWP
Thermo Scientific™

Orion™ Sodium Electrodes

Catalog number: 8611BNWP

Measure sodium in aqueous solutions quickly, accurately and economically with Thermo Scientific™ Orion™ Sodium Electrodes. A unique redox internal system with a Thermo Scientific™ Orion™ ROSS™ electrode provides faster response, and greater stability and accuracy than conventional sodium electrodes.

8611BNWP is a combination electrode with a Sure-Flow™ junction that allows easy cleaning. When conventional electrode junctions clog, the Sure-Flow junction can be opened and flushed clean simply by pressing the cap. 8411BN is a half cell sensor that requires ROSS reference electrode, Cat. No. 800300 or the ROSS Ultra reference electrode, Cat. No. 800500U to function.

 
Catalog Number
8611BNWP
Unit Size
Each
Connector Types
Waterproof BNC
Price (USD)
Availability
-
Full specifications
Quantity
Connector TypesWaterproof BNC
DescriptionROSS sodium combination electrode
Diameter (English) Body0.47 in
Diameter (Metric) Body12 mm
Filling Solution Type900010 for regular Na+ (> 10-5 M or 0.2 ppm)
900012 for low level Na+ (< 10-5 M or 0.2 ppm)
JunctionSure flow
Length (English)4.72 in
Length (English) Cable1M
Length (Metric)120 mm
Length (Metric) Cable39 in
MaterialGlass Body
Operating Range (Metric)1 x 10-6 M to saturated 0.02 ppm to saturated
Temperature (English) Operating32 to 176°F
For Use With (Equipment)ISE Meters
Temperature (Metric) Operating0°C to 100°C
Measurement Range1 x 10-6 M to saturated 0.02 ppm to saturated
ParameterSodium Combination Ion Selective Electrode
RefillableYes
Unit SizeEach
Catalog Number
Unit Size
Each
Connector Types
BNC
Price (USD)
Availability
-
Full specifications
Quantity
ApplicationsMeasures sodium in aqueous solution quickly, accurately, and economically; Unique redox internal system with ROSS™ electrode provides faster response, greater stability and accuracy than conventional sodium electrodes
Connector TypesBNC
DescriptionROSS half-cell BNC Orion sodium electrode
Diameter (English) Body0.47 in
Diameter (Metric) Body13 mm
Filling Solution Type900010 for regular Na+ (> 10-5 M or 0.2 ppm)
900012 for low level Na+ (< 10-5 M or 0.2 ppm)
Internal Reference800300 or 800500U
Length (English)4.72 in
Length (English) Cable1M
Length (Metric)121 mm
Length (Metric) Cable40 in
MaterialGlass Body
Operating Range (Metric)Saturated to 10-6 M, saturated to 0.02ppm
Temperature (English) Operating32 to 176°F
For Use With (Equipment)ISE Meters
Temperature (Metric) Operating0°C to 100°C
Measurement Range1 x 10-6 M to saturated 0.02 ppm to saturated
ParameterSodium Half-Cell Ion Selective Electrode
RefillableNo
Unit SizeEach
Showing 2 of 2
Catalog NumberSpecificationsUnit SizeConnector TypesPrice (USD)AvailabilityQuantity
8611BNWPFull specifications
EachWaterproof BNC
-
Connector TypesWaterproof BNC
DescriptionROSS sodium combination electrode
Diameter (English) Body0.47 in
Diameter (Metric) Body12 mm
Filling Solution Type900010 for regular Na+ (> 10-5 M or 0.2 ppm)
900012 for low level Na+ (< 10-5 M or 0.2 ppm)
JunctionSure flow
Length (English)4.72 in
Length (English) Cable1M
Length (Metric)120 mm
Length (Metric) Cable39 in
MaterialGlass Body
Operating Range (Metric)1 x 10-6 M to saturated 0.02 ppm to saturated
Temperature (English) Operating32 to 176°F
For Use With (Equipment)ISE Meters
Temperature (Metric) Operating0°C to 100°C
Measurement Range1 x 10-6 M to saturated 0.02 ppm to saturated
ParameterSodium Combination Ion Selective Electrode
RefillableYes
Unit SizeEach
8411BNFull specifications
EachBNC
-
ApplicationsMeasures sodium in aqueous solution quickly, accurately, and economically; Unique redox internal system with ROSS™ electrode provides faster response, greater stability and accuracy than conventional sodium electrodes
Connector TypesBNC
DescriptionROSS half-cell BNC Orion sodium electrode
Diameter (English) Body0.47 in
Diameter (Metric) Body13 mm
Filling Solution Type900010 for regular Na+ (> 10-5 M or 0.2 ppm)
900012 for low level Na+ (< 10-5 M or 0.2 ppm)
Internal Reference800300 or 800500U
Length (English)4.72 in
Length (English) Cable1M
Length (Metric)121 mm
Length (Metric) Cable40 in
MaterialGlass Body
Operating Range (Metric)Saturated to 10-6 M, saturated to 0.02ppm
Temperature (English) Operating32 to 176°F
For Use With (Equipment)ISE Meters
Temperature (Metric) Operating0°C to 100°C
Measurement Range1 x 10-6 M to saturated 0.02 ppm to saturated
ParameterSodium Half-Cell Ion Selective Electrode
RefillableNo
Unit SizeEach
Showing 2 of 2
The sodium electrode is commonly used to measure samples such as food, beverages and animal feed.

Features
8611BNWP is a combination electrode with  a Sure-Flow™ junction that allows easy cleaning. When conventional electrode junctions clog, the Sure-Flow junction can be opened and flushed clean simply by pressing the cap. 8411BN is a half cell sensor that requires ROSS reference electrode, Cat. No. 800300 or the ROSS Ultra reference electrode, Cat. No. 800500U to function.
 
Solutions required
Standards
941706 0.1 M NaCl sodium standard solution, 475 mL bottle
841108 1000 ppm sodium standard solution, 475 mL bottle
941107 100 ppm sodium standard solution, 475 mL bottle
941105 10 ppm sodium standard solution, 475 mL bottle
Known standards addition
841109 Sodium known addition standard, 1000 ppm with ISA, 475 mL bottle
650700 Sodium known addition standard, 1 M with ISA, 475 mL bottle
ISA
841111 Sodium ISA, 475 mL bottle
Electrode fill solution
900010 ROSS sodium and reference electrode filling solution, 5 x 50 mL bottles. 
                For regular sodium measurements (> 10-5 M or 0.2 ppm)
900012 ROSS sodium and reference electrode  filling solution, 5 x 50 mL bottles. 
                For low-level sodium measurements (< 10-5M or 0.2 ppm)
Storage solution
841101 Sodium electrode storage solution, 475 mL bottle
Recondition solution 
841113 Sodium electrode reconditioning solution, 475 mL bottle
 
Items included with
841113 Sodium electrode reconditioning solution, 475 mL bottle
841111 Sodium ISA, 475 mL bottle
841109 Sodium known addition standard, 1000 ppm with ISA, 475 mL bottle
841108 1000 ppm sodium standard solution, 475 mL bottle
900010 ROSS sodium and reference electrode. 60mL 1 bottle
841101 Sodium electrode storage solution, 475 mL bottle
 
Warranty period
12 months from date of purchase by Buyer or 18 months from date of shipment from Seller, whichever is earlier.
 

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text