Are Thermo Scientific AbClarify antibody clean-up kits and spin columns suitable for small-scale or analytical purification?
Yes, researchers can use Thermo Scientific AbClarify antibody clean-up kits and spin columns for small-scale, rapid cleanup prior to downstream applications such as ELISA, Western blotting, or labeling.
Why does my antibody appear in the flow-through instead of binding when using Thermo Scientific AbClarify antibody clean-up kits and spin columns?
Thermo Scientific AbClarify antibody clean-up kits and spin columns use a negative selection mechanism (non-IgG proteins bind, IgG flows through). This is expected behavior—the antibody is collected in the flow-through, not eluted.
What antibody storage buffers are compatible with Thermo Scientific AbClarify antibody clean-up kits and spin columns?
Thermo Scientific AbClarify antibody clean-up kits and spin columns perform best with input samples in standard physiological buffers/media at neutral pH prior to dilution with the recommended equilibration buffer. Samples containing high salt, detergents, or extreme pH may reduce performance and may need to be buffer exchanged into the recommended equilibration buffer prior to purification.
Can Thermo Scientific AbClarify antibody clean-up kits and spin columns be used for antibody purification from serum?
Yes, Thermo Scientific AbClarify antibody clean-up kits and spin columns are specifically designed for rapid IgG purification from serum, with minimal hands-on time and no need for low pH elution.
Can Thermo Scientific AbClarify antibody clean-up kits and spin columns be used with antibodies conjugated to labels or tags?
Thermo Scientific AbClarify antibody clean-up kits and spin columns have not been tested with labeled antibodies, and conjugation (e.g., enzymes, fluorophores) may alter purification behavior. Recovery should be tested before scaling up.
Why am I seeing low yield or antibody loss after purification when using Thermo Scientific AbClarify antibody clean-up kits and spin columns?
Low yield when using Thermo Scientific AbClarify antibody clean-up kits and spin columns is commonly due to:
- Antibody not flowing through efficiently due to its pI
- Incorrect equilibration buffer
- Overloading or improper equilibration
Running a small-scale test and confirming buffer conditions usually resolves this.
Which species’ antibodies are compatible with Thermo Scientific AbClarify antibody clean-up kits and spin columns?
Thermo Scientific AbClarify antibody clean-up kits and spin columns have been tested for purification of human, mouse (including IgG1, IgG2a, IgG2b), rabbit, rat, sheep, and dog antibodies. Researchers frequently ask about pig, goat, or other species—these may work, but recovery should be validated experimentally.
Can Thermo Scientific AbClarify antibody clean-up kits and spin columns be used with my specific antibody?
Thermo Scientific AbClarify antibody clean-up kits and spin columns are optimized for purification of most IgG antibodies from plasma, serum, or cell culture supernatant, but performance can vary by clone, subclass, and species. Some antibodies (especially certain monoclonals or IgGs with unusually low pI) may show reduced recovery.
Can I use Thermo Scientific AbClarify antibody clean-up kits and spin columns to buffer exchange/desalt my sample?
Yes, Thermo Scientific AbClarify antibody clean-up kits and spin columns can remove small molecules such as glycerol and buffer salts.
Can I use Thermo Scientific AbClarify antibody clean-up kits and spin columns to purify IgA and/or IgM from my serum samples?
Thermo Scientific AbClarify antibody clean-up kits and spin columns are designed for the purification of IgG from serum with 80% recovery of IgG and greater than 90% purity. Although IgA and IgM may be present along with the purified IgG, a high percentage (>80%) of IgA and IgM is typically retained on the resin. This high binding of IgA and IgM to the resin combined with the fact that IgA and IgM are present in low abundance in serum results in low levels of these antibody molecules in the purified IgG. We offer other products (e.g. affinity resins) specifically for IgA and IgM purification.
Are Thermo Scientific AbClarify antibody clean-up kits and spin columns sterile or endotoxin-free?
No, Thermo Scientific AbClarify antibody clean-up kits and spin columns are not tested for nor certified sterile or endotoxin-free.
Can I reuse Thermo Scientific AbClarify antibody clean-up kits and spin columns?
We have not tested the reusability of Thermo Scientific AbClarify antibody clean-up kits and spin columns, and they are designed to be single use only.
Can I elute bound contaminants from Thermo Scientific AbClarify antibody clean-up kits and spin columns?
We have not extensively tested elution conditions for recovering contaminants from Thermo Scientific AbClarify antibody clean-up kits and spin columns. Buffer containing 500 mM NaCl can be used to recover retained antibody and BSA however the recovery of other bound species has not been established. The chemical compatibility of the Thermo Scientific AbClarify resin has also not been extensively tested.
What is the BSA or gelatin binding capacity of Thermo Scientific AbClarify antibody clean-up kits and spin columns?
The Thermo Scientific AbClarify resin does not have a defined binding capacity for BSA, gelatin, or contaminating proteins because contaminant removal depends on the sample composition and the proteins present. As a general guide, refer to the recommended sample volumes for each sample type, which provide an estimate of the contaminant load that can typically be processed with each format.
Can I use a different buffer besides the one recommended for my sample when using Thermo Scientific AbClarify antibody clean-up kits and spin columns?
During development, we found that several alternative equilibration buffers were effective in some applications. However, the buffers provided in the user guide were selected because they were the most broadly applicable across the samples tested. Other buffers may be compatible with Thermo Scientific AbClarify antibody clean-up kits and spin columns, but they should be tested for the specific application.
Why are certain samples only recommended on certain Thermo Scientific AbClarify column formats? Is the resin the same in the different formats?
Yes, the resin is the same however the path length differs in the various Thermo Scientific AbClarify column formats which affects the purification. Suboptimal purification may be observed if the recommended format is not used for the particular sample.
What should I do if my antibody is not recovered after purification when using Thermo Scientific AbClarify antibody clean-up kits and spin columns?
If the antibody is not recovered when using Thermo Scientific AbClarify antibody clean-up kits and spin columns, first apply a chase volume of equilibration buffer equal to 10% of the resin bed volume (e.g., 200 µL for a 2 mL column) and centrifuge again to recover any antibody remaining in the column. If the antibody is still not recovered, it may have been retained on the AbClarify resin. In a small percentage of cases (<5%), antibodies with unusually low isoelectric points (pI) may interact with the resin and remain bound to the column. To recover the antibody, apply buffer containing 500 mM NaCl to the column, incubate for 30 minutes at room temperature, then centrifuge to collect the sample. Under these conditions, both the antibody and BSA are expected to be recovered together.
What can I do to maximize antibody recovery with Thermo Scientific AbClarify antibody clean-up kits and spin columns?
We recommend performing a dry spin, then using a stacker and chase volume when working with 100 ul antibody samples on the 2 mL AbClarify columns. After Wash 3, perform a dry spin by centrifuging at 700 × g for 3 minutes. Apply the sample, and once the sample has entered the resin bed, apply a 20 ul stacker volume of equilibration buffer and centrifuge to collect the purified antibody. Then apply a chase volume of equilibration buffer equal to 10% of the resin bed volume (e.g. 200 ul for a 2 ml column) and centrifuge again to recover any antibody remaining in the column. While this approach can improve antibody recovery with Thermo Scientific AbClarify antibody clean-up kits and spin columns, it will increase the final sample volume and may require a downstream concentration step.
What can I do to minimize sample dilution with Thermo Scientific AbClarify antibody clean-up kits and spin columns?
We recommend performing a dry spin, especially when working with <100 ul samples on the 2 mL AbClarify columns. After Wash 3, perform a dry spin by centrifuging at 700 × g for 3 minutes, then apply the sample.