Thermo Scientific™

Heratherm Incubation Chamber 750L

Catalog number: EIS750
Thermo Scientific™

Heratherm Incubation Chamber 750L

Catalog number: EIS750
Produces precise temperature conditions above and below ambient, ideally suited for microbiological incubation, and heated or cooled incubated storage.
 
Catalog Number
EIS750
Unit Size
Each
Door Style
Solid outer door with inner glass door
Shipping Weight (English)
840 lbs
Shipping Weight (Metric)
381 kg
Price (USD)
Full specifications
Alarm TypesAudible and Visible
Capacity (English)26.5 cu.ft.
Capacity (English) Shelf66.1 lbs
Capacity (Metric) Shelf30 kg
Certifications/ComplianceUL, CE
Data OutputsUSB, Ethernet
Capacity (Metric)750 L
Chamber MaterialPowder-coated Cold Rolled Steel
LightingNo
MaterialPowder-coated Cold Rolled Steel
No. of Shelves3
Plug TypeNema 5-20P
Relative Humidity10 to 90%
Temperature Range (Metric)0 to 70°C
TypeEnvironmental Chamber
Display7 in. touchscreen user interface
Door StyleSolid outer door with inner glass door
No. of Casters4
Ports2 access ports
ProgrammabilityTemperature ramping
Resolution0.1°C
Shelf Area (English)4.9 ft.²
Shelf Area (Metric) 0.46 m²
Shelf MaterialStainless Steel (304/1.4301)
Temperature ControlMicroprocessor - programmable
Temperature Stability≤ ±0.1°C @ 20°C to 37°C
Temperature Uniformity≤ ±0.5°C @ 20°C to 37°C
Warranty24 months
Width (English)42.52 in.
Width (English) Interior33.07 in.
Width (English) Shelf22.6 in.
Width (Metric)1080 mm
Width (Metric) Interior840 mm
Width (Metric) Shelf795 mm
Height (English)72.24 in.
Height (English) Interior57.09 in
Height (Metric)1835 mm
Height (Metric) Interior1450 mm
Depth (English)34.84 in.
Depth (English) Interior24.8 in.
Depth (Metric)885 mm
Depth (Metric) Interior630 mm
Shipping Weight (English)840 lbs
Shipping Weight (Metric)381 kg
Electrical Requirements100 - 240V, 50-60Hz, 1400W
Voltage100/115/220/230 V
Wattage900 W
Unit SizeEach
Catalog Number
Unit Size
Each
Door Style
Glass door
Shipping Weight (English)
820 lbs
Shipping Weight (Metric)
372 kg
Price (USD)
Full specifications
Alarm TypesAudible and Visible
Capacity (English)26.5 cu. ft.
Capacity (English) Shelf66.1 lbs
Capacity (Metric) Shelf30 kg
Certifications/ComplianceUL, CE
Data OutputsUSB, Ethernet
Capacity (Metric)750 L
Chamber MaterialPowder-coated Cold Rolled Steel
LightingNo
MaterialPowder-coated Cold Rolled Steel
No. of Shelves3
Plug TypeNema 5-20P
Relative Humidity10 to 90%
Temperature Range (Metric)0 to 70°C
TypeEnvironmental Chamber
Display7 in. touchscreen user interface
Door StyleGlass door
No. of Casters4
Ports2 access ports
ProgrammabilityTemperature ramping
Shelf Area (English) 4.9 ft²
Shelf Area (Metric) 0.46 m²
Shelf MaterialStainless Steel (304/1.4301)
Temperature ControlMicroprocessor - programmable
Temperature Resolution0.1°C
Temperature Stability≤ ±0.1°C @ 20°C to 37°C
Temperature Uniformity≤ ±0.5°C @ 20°C to 37°C
Warranty24 months
Width (English)42.52 in.
Width (English) Interior33.07 in.
Width (English) Shelf22.6 in.
Width (Metric)1080 mm
Width (Metric) Interior840 mm
Width (Metric) Shelf795 mm
Height (English)72.24 in.
Height (English) Interior57.09 in
Height (Metric)1835 mm
Height (Metric) Interior1450 mm
Depth (English)34.84 in.
Depth (English) Interior24.8 in.
Depth (Metric)885 mm
Depth (Metric) Interior630 mm
Shipping Weight (English)820 lbs
Shipping Weight (Metric)372 kg
Electrical Requirements100 - 240V, 50-60Hz, 1400W
Voltage100/115/220/230 V
Wattage900 W
Unit SizeEach
Showing 2 of 2
Catalog NumberSpecificationsUnit SizeDoor StyleShipping Weight (English)Shipping Weight (Metric)Price (USD)
EIS750Full specifications
EachSolid outer door with inner glass door840 lbs381 kgRequest A Quote
Alarm TypesAudible and Visible
Capacity (English)26.5 cu.ft.
Capacity (English) Shelf66.1 lbs
Capacity (Metric) Shelf30 kg
Certifications/ComplianceUL, CE
Data OutputsUSB, Ethernet
Capacity (Metric)750 L
Chamber MaterialPowder-coated Cold Rolled Steel
LightingNo
MaterialPowder-coated Cold Rolled Steel
No. of Shelves3
Plug TypeNema 5-20P
Relative Humidity10 to 90%
Temperature Range (Metric)0 to 70°C
TypeEnvironmental Chamber
Display7 in. touchscreen user interface
Door StyleSolid outer door with inner glass door
No. of Casters4
Ports2 access ports
ProgrammabilityTemperature ramping
Resolution0.1°C
Shelf Area (English)4.9 ft.²
Shelf Area (Metric) 0.46 m²
Shelf MaterialStainless Steel (304/1.4301)
Temperature ControlMicroprocessor - programmable
Temperature Stability≤ ±0.1°C @ 20°C to 37°C
Temperature Uniformity≤ ±0.5°C @ 20°C to 37°C
Warranty24 months
Width (English)42.52 in.
Width (English) Interior33.07 in.
Width (English) Shelf22.6 in.
Width (Metric)1080 mm
Width (Metric) Interior840 mm
Width (Metric) Shelf795 mm
Height (English)72.24 in.
Height (English) Interior57.09 in
Height (Metric)1835 mm
Height (Metric) Interior1450 mm
Depth (English)34.84 in.
Depth (English) Interior24.8 in.
Depth (Metric)885 mm
Depth (Metric) Interior630 mm
Shipping Weight (English)840 lbs
Shipping Weight (Metric)381 kg
Electrical Requirements100 - 240V, 50-60Hz, 1400W
Voltage100/115/220/230 V
Wattage900 W
Unit SizeEach
EIG750Full specifications
EachGlass door820 lbs372 kgRequest A Quote
Alarm TypesAudible and Visible
Capacity (English)26.5 cu. ft.
Capacity (English) Shelf66.1 lbs
Capacity (Metric) Shelf30 kg
Certifications/ComplianceUL, CE
Data OutputsUSB, Ethernet
Capacity (Metric)750 L
Chamber MaterialPowder-coated Cold Rolled Steel
LightingNo
MaterialPowder-coated Cold Rolled Steel
No. of Shelves3
Plug TypeNema 5-20P
Relative Humidity10 to 90%
Temperature Range (Metric)0 to 70°C
TypeEnvironmental Chamber
Display7 in. touchscreen user interface
Door StyleGlass door
No. of Casters4
Ports2 access ports
ProgrammabilityTemperature ramping
Shelf Area (English) 4.9 ft²
Shelf Area (Metric) 0.46 m²
Shelf MaterialStainless Steel (304/1.4301)
Temperature ControlMicroprocessor - programmable
Temperature Resolution0.1°C
Temperature Stability≤ ±0.1°C @ 20°C to 37°C
Temperature Uniformity≤ ±0.5°C @ 20°C to 37°C
Warranty24 months
Width (English)42.52 in.
Width (English) Interior33.07 in.
Width (English) Shelf22.6 in.
Width (Metric)1080 mm
Width (Metric) Interior840 mm
Width (Metric) Shelf795 mm
Height (English)72.24 in.
Height (English) Interior57.09 in
Height (Metric)1835 mm
Height (Metric) Interior1450 mm
Depth (English)34.84 in.
Depth (English) Interior24.8 in.
Depth (Metric)885 mm
Depth (Metric) Interior630 mm
Shipping Weight (English)820 lbs
Shipping Weight (Metric)372 kg
Electrical Requirements100 - 240V, 50-60Hz, 1400W
Voltage100/115/220/230 V
Wattage900 W
Unit SizeEach
Showing 2 of 2
  • Uniform Temperature throughout the chamber.
  • Energy-efficient Peltier technology supports temperature stability and uniformity with lower energy usage compared to traditional compressors and without hazardous refrigerant.
  • Intuitive touchscreen interface with easy programmability of temperature cycles and process duration.
  • Two access ports for independent data capture, and internal documentation of set and actual parameter values, along with event log to meet 21 CFR Part 11 requirements for process documentation.
  • Data retrieval via USB stick, Ethernet connection, or Thermo Cloud via OPC-UA standard.
  • Sample and process protection: Assign personalized access with user IDs; restrict access with standard door lock, or optional automated door lock; various alarm options to prevent operator of process issues.
  • Simplified setup with no technician required; install using standard power cord.
  • IQ/OQ qualifications and other services available; visit thermofisher.com/chamberservice.
  • Inner glass door keeps environment stable, even when opening outer door. Glass door also available.
  • Rounded corners and removable shelving offer easy cleaning to help prevent cross-contamination.
  • Duplex interior electrical sockets for use of stirrers, shakers or other equipment inside the chamber are available as a factory-installed option. Choose from a variety of country-specific sockets. (Ordered with separate order code)

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text