Thermo Scientific™

Orbitrap Fusion™ Tribrid™ Mass Spectrometer

Catalog number: IQLAAEGAAPFADBMBCX
Thermo Scientific™

Orbitrap Fusion™ Tribrid™ Mass Spectrometer

Catalog number: IQLAAEGAAPFADBMBCX
Meet your most challenging biological research objectives using the Thermo Scientific™ Orbitrap Fusion™ Tribrid™ Mass Spectrometer. This instrument combines the best of quadrupole, ion trap and Orbitrap mass analysis in a revolutionary Tribrid architecture to provide unprecedented depth of analysis and ease of use. Innovative software and instrument design let you concentrate on your science rather than method development and instrument operation.
 
Catalog Number
IQLAAEGAAPFADBMBCX
Unit Size
Each
Description
Orbitrap Fusion Tribrid Mass Spectrometer
Price (USD)
Full specifications
Mass Range50 to 6000 m/z
TypeOrbitrap LC-MS
Dynamic Range>5000:1
Mass AccuracyInternal: <1-ppm RMS
External: <3-ppm RMS
Polarity SwitchingOne Full Cycle in <1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000))
SensitivityMS/MS: 100 fg Reserpine on Column S/N 100:1; test requires HESI II probe
Resolution450,000
Item DescriptionOrbitrap Fusion Tribrid Mass Spectrometer
DescriptionOrbitrap Fusion Tribrid Mass Spectrometer
Scan RatesMSn for n=1 Through 10
Weight (Metric)318 kg (700 lbs) with table but without data system, vacuum rough pumps, and optional items
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
IQLAAEGAAPFADBMBCXFull specifications
EachOrbitrap Fusion Tribrid Mass SpectrometerRequest A Quote
Mass Range50 to 6000 m/z
TypeOrbitrap LC-MS
Dynamic Range>5000:1
Mass AccuracyInternal: <1-ppm RMS
External: <3-ppm RMS
Polarity SwitchingOne Full Cycle in <1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000))
SensitivityMS/MS: 100 fg Reserpine on Column S/N 100:1; test requires HESI II probe
Resolution450,000
Item DescriptionOrbitrap Fusion Tribrid Mass Spectrometer
DescriptionOrbitrap Fusion Tribrid Mass Spectrometer
Scan RatesMSn for n=1 Through 10
Weight (Metric)318 kg (700 lbs) with table but without data system, vacuum rough pumps, and optional items
Unit SizeEach
Showing 1 of 1
The Orbitrap Fusion Tribrid Mass Spectrometer enables scientists analyzing the most challenging low-abundance, high-complexity samples to identify more compounds faster, quantify more accurately and elucidate structures more thoroughly.

 

Uncompromising Performance

  • Ultrahigh resolution up to 500,000 FWHM removes interferences
  • Precursor selection using a quadrupole mass filter allows the ion trap and Orbitrap mass analyzers to operate in parallel for excellent sensitivity and selectivity
  • Multiple dissociation techniques—CID, HCD, and optional ETD—with ion trap or Orbitrap detection at any level of MSn maximize flexibility for research applications
  • Flexibility of fragmentation—CID-HCD, HCD-CID, and HCD-HCD—at any stage of MSn analysis with fragment ions detected by either mass analyzer enables detailed structure determination of metabolites, glycans and other small molecules
  • Active beam guide with axial field reduces noise and increases robustness
  • Novel Orbitrap analyzer design and dual-pressure ion trap configuration provide fast MS/MS scan rates up to 20 Hz with unmatched spectral quality
  • Thermo Scientific™ Easy-Max NG™ and optional Thermo Scientific™ Ion Max NG™ and Nanospray Flex NG™ ion sources deliver next-generation performance

Unrivaled Proteomics Capabilities

  • Wide dynamic range and ultrahigh mass resolution allow identification of more low-abundance proteins with confidence
  • Ultrahigh mass resolution is ideal for analysis of monoclonal antibodies and other intact proteins
  • Sub-1-ppm mass accuracy provided by the optional Thermo Scientific™ EASY-IC™ ion source with internal calibration adds confidence to protein quantification results
  • Automated Synchronous Precursor Selection (SPS) for MS3 significantly increases the number of peptides and proteins identified and improves quantitative accuracy when using isobaric mass tags
  • Simple, reliable Thermo Scientific™ EASY-ETD™ ion source (optional) complements CID and HCD data and enhances characterization of complex P™s
  • Fast scanning yields more MSn data from a single run, enabling accurate structural characterization on a UHPLC timescale

Easy-to-Use

  • Dynamic Scan Management helps users get the maximum information from samples with ease, scheduling scan events most efficiently and intelligently matching each precursor with the optimum fragmentation mode and mass analyzer
  • A library of templates with application-specific defaults for common experiments simplifies method development
  • Compatibility with Thermo Scientific™ Compound Discoverer™, Mass Frontier™, Pinpoint™, Protein Deconvolution, Proteome Discoverer™, ProSightPC, and SIEVE™ software for increased productivity in specific applications