Search Thermo Fisher Scientific
Search Thermo Fisher Scientific
Burette Functions | Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc |
Functions Available | Sample titration, titrant standardization, calibration and direct measure |
Accuracy (mV) | ±0.2 mV |
Accuracy (Temperature) | ±0.2 °C |
Alarm Output | Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder |
Backlight Option | Yes, adjustable |
Blank Options | Fixed value or variable value using titration |
Burette Sizes | 10 mL, 20 mL (included) or 50 mL |
Calibration | mV and temperature |
Calibration Points | 1 point relative mV (RmV) mode |
Certifications/Compliance | CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010 |
Channels | 1 |
Cycles Per Titration Run | 1 to 5 cycles, option to exclude cycle results from average results and RSD calculations |
Data Management Details | Data log export as CSV or PDF file, short or long format |
Data Points | 100 data sets each: sample titration, titrant standardization, calibration and direct measure |
Description | Orion Star T920 redox titrator standard kit |
Display Type | 5.7” color capacitive touchscreen, 640 x 480 resolution |
Type | Redox titrator |
Equivalence Points | 1 to 2 |
For Use With (Application) | Redox titrations including sulfite/SO2 and reducing sugar in juice and wine, ascorbic acid (vitamin C) and peroxide value in food products, dissolved oxygen in wastewater by Winkler titration and organic matter in soil |
Includes | 9778BNWP glass-body redox electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies |
Inputs | BNC (redox/ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
IP Rating | IP-51 |
Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish |
Material | ABS Plastic |
Memory | Non-volatile memory preserves data logs and settings |
Methods | Up to 10 methods with optional password protection; import/export methods via USB flash drive |
Model | Orion Star T920 |
Outputs | 3 USB ports for printer, USB flash drive and computer software connections |
Precision | 0.5% RSD, dependent on environment and handling conditions |
Preset Endpoints | 1 to 3 |
Probe Type | Redox/ORP electrode, reference half-cell electrode, ATC temperature probe, stirrer probe |
Range (mV) | -2000.0 to +2000.0 mV |
Relative Humidity Range | 5 to 85%, non-condensing |
Resolution | Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range) |
Resolution (mV) | 0.1 mV |
Resolution (Temperature) | 0.1 °C |
Sample ID | Auto-incremental, manual or off |
Stirrer Probe Speeds | 5 user selectable speeds (250 to 3700 RPM) |
Temperature (English) Operating | 41°F to 104°F |
Temperature (Metric) Operating | 5°C to 40°C |
Temperature Probe Calibration | Optional 1 point offset calibration |
Temperature Range (Metric) | -5.0°C to +100.0°C |
Temperature Selection | Manual or automatic |
Time and Date | Yes, with nonvolatile battery backup |
Titrant Determination | Standardization titration or manual concentration input |
Titration Process Control | Routine, quick, careful or user defined |
Titration Setup Wizard | Yes, using Start a New Titration workflow |
Titration Technique | Equivalence point or preset endpoint |
Titration Types | Direct or back titration |
Updateable Firmware | Yes, using USB flash drive |
Warranty | 1 year replacement warranty |
Dimensions (L x W x H) | 10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm |
Electrical Requirements | 100-240V, 50/60 Hz |
Unit Size | Each |
Burette Functions | Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc |
Functions Available | Sample titration, titrant standardization, calibration and direct measure |
Accuracy (mV) | ±0.2 mV |
Accuracy (Temperature) | ±0.2 °C |
Alarm Output | Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder |
Backlight Option | Yes, adjustable |
Blank Options | Fixed value or variable value using titration |
Burette Sizes | 10 mL, 20 mL (included) or 50 mL |
Calibration | mV and temperature |
Calibration Points | 1 point relative mV (RmV) mode |
Certifications/Compliance | CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010 |
Channels | 1 |
Cycles Per Titration Run | 1 to 5 cycles, option to exclude cycle results from average results and RSD calculations |
Data Management Details | Data log export as CSV or PDF file, short or long format |
Data Points | 100 data sets each: sample titration, titrant standardization, calibration and direct measure |
Description | Orion Star T920 redox titrator without electrode |
Display Type | 5.7” color capacitive touchscreen, 640 x 480 resolution |
Type | Redox titrator |
Equivalence Points | 1 to 2 |
For Use With (Application) | Redox titrations including sulfite/SO2 and reducing sugar in juice and wine, ascorbic acid (vitamin C) and peroxide value in food products, dissolved oxygen in wastewater by Winkler titration and organic matter in soil |
Includes | 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies |
Inputs | BNC (redox/ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
IP Rating | IP-51 |
Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish |
Material | ABS Plastic |
Memory | Non-volatile memory preserves data logs and settings |
Methods | Up to 10 methods with optional password protection; import/export methods via USB flash drive |
Model | Orion Star T920 |
Outputs | 3 USB ports for printer, USB flash drive and computer software connections |
Precision | 0.5% RSD, dependent on environment and handling conditions |
Preset Endpoints | 1 to 3 |
Probe Type | Redox/ORP electrode, reference half-cell electrode, ATC temperature probe, stirrer probe |
Range (mV) | -2000.0 to +2000.0 mV |
Relative Humidity Range | 5 to 85%, non-condensing |
Resolution | Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range) |
Resolution (mV) | 0.1 mV |
Resolution (Temperature) | 0.1 °C |
Sample ID | Auto-incremental, manual or off |
Stirrer Probe Speeds | 5 user selectable speeds (250 to 3700 RPM) |
Temperature (English) Operating | 41°F to 104°F |
Temperature (Metric) Operating | 5°C to 40°C |
Temperature Probe Calibration | Optional 1 point offset calibration |
Temperature Range (Metric) | -5.0°C to +100.0°C |
Temperature Selection | Manual or automatic |
Time and Date | Yes, with nonvolatile battery backup |
Titrant Determination | Standardization titration or manual concentration input |
Titration Process Control | Routine, quick, careful or user defined |
Titration Setup Wizard | Yes, using Start a New Titration workflow |
Titration Technique | Equivalence point or preset endpoint |
Titration Types | Direct or back titration |
Updateable Firmware | Yes, using USB flash drive |
Warranty | 1 year replacement warranty |
Dimensions (L x W x H) | 10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm |
Electrical Requirements | 100-240V, 50/60 Hz |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Includes | Price (USD) | Availability | Quantity | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
START9201 | Each | Orion Star T920 redox titrator standard kit | 9778BNWP glass-body redox electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies | Price: 4,350.00 Your price: | - | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
START9200 | Each | Orion Star T920 redox titrator without electrode | 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies | Price: 4,190.00 Your price: | - | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
•Accurate, reproducible results: Automating the titration workflow enables analysis to be run using the same setup parameters and calculations every time
•Faster setup time: Setup and save electrode, titrant and titration parameters once using methods
•Improved lab throughput: Start the titration and let the instrument run unattended
•Reduced cost and downtime: Easily replace titrator parts to minimize maintenance downtime while long lasting electrodes reduce the cost of ownership
•Securely document test results: View results live, in the summary table and within the 100 point data log
•Applications database: Tested and validated preprogrammed methods can be loaded onto your titrator
•Standard kit with 9778BNWP redox electrode is ideal for most standard redox titrations with its robust glass body for chemical resistance in a variety of samples