Shop All Gene-Specific Arrays

TaqMan™ Array Human JAK-STAT Pathway Applied Biosystems™

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human JAK-STAT Pathway 96-well Plate contains 92 assays to genes associated with JAK-STAT pathways and 4 assays to candidate endogenous control genes.

TaqMan™ Array Human Alzheimer's Disease Applied Biosystems™

The Applied Biosystems® TaqMan® Array Human Alzheimer's Disease 96-well Plate contains 92 assays to Alzheimer's associated genes and 4 assays to candidate endogenous control genes.

The panel of assays in this plate is based on the "amyloid hypothesis". The 92 genes are involved in APP processes that generate beta-amyloid and included genes implicated in multiple secondary steps of beta-amyloid aggregation, tau hyperphosphorylation, excitotoxicity, inflammation, oxidation and microglial activation. We also include assays for genes involved in cholesterol biosynthesis due to the correlation between high cholesterol and increased risk of Alzheimer's. Genes associated with Alzheimer's disease pathology, biochemistry and genetics are also included. Gene Signature Plates are 96-well plates that are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment.

• Affordable; minimum order of three plates; ideal for small, medium or large-sized projects
• Fast delivery; on your bench in days
• Convenient; dried PCR primer and TaqMan® probe sets supplied in a 96- well plate; just add master mix and your sample
• Same TaqMan®Assay Quality, New Format

TaqMan® Array Plates contain the same high quality TaqMan® Gene Expression Assays (PCR primers and TaqMan® probe sets) that have been commercially available for years in a convenient, dried, 96-well format. Extensive tests have found no difference in performance between TaqMan®Assays supplied in the traditional liquid format and assays dried into a TaqMan® Array Plate. Figure 1 shows the results of an experiment comparing the linear range of the two formats, where no difference in performance was observed.

Just Add Master Mix and Sample, and Begin Cycling
Ideal for projects such as validation of microarray and RNAi data, and pathway studies, the plates include just the right amount of TaqMan®Assay in each well: enough for one 20 µl reaction. You can order as few as three Gene Signature Plates, making these an affordable option for many laboratories and minimizing the waste of unused individually purchased TaqMan®Assays. Save a significant amount of time setting up your experiments. Just add master mix and sample, and begin cycling.

Figure 2 is an example Plate Layout with Gene Symbols and Assay IDs

Plate Map Ensures Proper Data Labeling and Easy Re-Ordering
Each pack of TaqMan® Array Plates is shipped with a CD containing the plate configuration map (see Figure 2) along with the details of each TaqMan®Assay. This information is imported into the real-time PCR instrument to enable proper labeling of experimental data and easy access to Assay ID numbers for simple reordering.

Simple to Use
Each TaqMan® Array Plate well contains a single TaqMan®Assay for one 20 µl reaction. The plates can be stored at room temperature or at 4°C. When you are ready to run your assays, simply add PCR master mix and your cDNA sample, seal the plate, and begin cycling on a real-time PCR instrument.

Compatibility
TaqMan® Array Plates have been optimized for use with TaqMan® Gene Expression Master Mix, but are also compatible with TaqMan® Universal PCR Master Mix. For studies using cultured cells, TaqMan® Array Plates are also compatible (and recommended) with the TaqMan® Gene Expression Cells-to-Ct™ Kit. TaqMan® Array Plates must be run on a real-time PCR instrument with 96-well plate capability. The plates have been validated for use on Applied Biosystems® 7000, 7300, 7500 and 7900HT Fast Real-Time PCR Systems using standard 96-well blocks, standard PCR cycling conditions, and 20 µl reaction

TaqMan™ Array Human Growth Factors Applied Biosystems™

The Applied Biosystems® TaqMan® Array Human Growth Factors 96-well Plate contains 92 assays to human growth factor associated genes and 4 assays to candidate endogenous control genes.

The panel of assays in the TaqMan® Array Human Growth Factors 96-well Plate targets genes involved in the coding of specific growth factor proteins. Also on the panel are genes involved in cell differentiation, regulation of apoptosis, angiogenic growth factors, embryonic development, and tissue-specific development.

The panel of assays in the TaqMan® Array Human Growth Factors 96-well Plate targets genes involved in the coding of specific growth factor proteins. Also on the panel are genes involved in cell differentiation, regulation of apoptosis, angiogenic growth factors, embryonic development, and tissue-specific development. Gene Signature Plates are 96-well plates that are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment.

• Affordable; minimum order of three plates; ideal for small, medium or large-sized projects
• Fast delivery; on your bench in days
• Convenient; dried PCR primer and TaqMan® probe sets supplied in a 96- well plate; just add master mix and your sample
• Same TaqMan®Assay Quality, New Format

TaqMan® Array Plates contain the same high quality TaqMan® Gene Expression Assays (PCR primers and TaqMan® probe sets) that have been commercially available for years in a convenient, dried, 96-well format. Extensive tests have found no difference in performance between TaqMan®Assays supplied in the traditional liquid format and assays dried into a TaqMan® Array Plate. Figure 1 shows the results of an experiment comparing the linear range of the two formats, where no difference in performance was observed.

Just Add Master Mix and Sample, and Begin Cycling
Ideal for projects such as validation of microarray and RNAi data, and pathway studies, the plates include just the right amount of TaqMan®Assay in each well: enough for one 20 µl reaction. You can order as few as three Gene Signature Plates, making these an affordable option for many laboratories and minimizing the waste of unused individually purchased TaqMan®Assays. Save a significant amount of time setting up your experiments. Just add master mix and sample, and begin cycling.

Figure 2 is an example Plate Layout with Gene Symbols and Assay IDs

Plate Map Ensures Proper Data Labeling and Easy Re-Ordering
Each pack of TaqMan® Array Plates is shipped with a CD containing the plate configuration map (see Figure 2) along with the details of each TaqMan®Assay. This information is imported into the real-time PCR instrument to enable proper labeling of experimental data and easy access to Assay ID numbers for simple reordering.

Simple to Use
Each TaqMan® Array Plate well contains a single TaqMan®Assay for one 20 µl reaction. The plates can be stored at room temperature or at 4°C. When you are ready to run your assays, simply add PCR master mix and your cDNA sample, seal the plate, and begin cycling on a real-time PCR instrument.

Compatibility
TaqMan® Array Plates have been optimized for use with TaqMan® Gene Expression Master Mix, but are also compatible with TaqMan® Universal PCR Master Mix. For studies using cultured cells, TaqMan® Array Plates are also compatible (and recommended) with the TaqMan® Gene Expression Cells-to-Ct™ Kit. TaqMan® Array Plates must be run on a real-time PCR instrument with 96-well plate capability. The plates have been validated for use on Applied Biosystems® 7000, 7300, 7500 and 7900HT Fast Real-Time PCR Systems using standard 96-well blocks, standard PCR cycling conditions, and 20 µl reaction volumes.

TaqMan™ Array, Human Alzheimer's Disease, Fast 96-well Applied Biosystems™

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The panel of assays in the TaqMan® Array 96-well Human Alzheimer's Disease Plate is based on the 'amyloid hypothesis’. The 92 genes are involved in APP processes that generate beta-amyloid and included genes implicated in multiple secondary steps of beta-amyloid aggregation, tau hyperphosphorylation, excitotoxicity, inflammation, oxidation and microglial activation. We also include assays for genes involved in cholesterol biosynthesis due to the correlation between high cholesterol and increased risk of Alzheimer's. Genes associated with Alzheimer's disease pathology, biochemistry and genetics are also included.

TaqMan™ Array Human PDGF Pathway Applied Biosystems™

The Applied Biosystems® TaqMan® Array Human PDGF Pathway 96-well Plate contains 92 assays to PDGF pathway associated genes and 4 assays to candidate endogenous control genes. Gene Signature Plates are 96-well plates that are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment.

• Affordable; minimum order of three plates; ideal for small, medium or large-sized projects
• Fast delivery; on your bench in days
• Convenient; dried PCR primer and TaqMan® probe sets supplied in a 96- well plate; just add master mix and your sample
• Same TaqMan®Assay Quality, New Format

TaqMan® Array Plates contain the same high quality TaqMan® Gene Expression Assays (PCR primers and TaqMan® probe sets) that have been commercially available for years in a convenient, dried, 96-well format. Extensive tests have found no difference in performance between TaqMan®Assays supplied in the traditional liquid format and assays dried into a TaqMan® Array Plate. Figure 1 shows the results of an experiment comparing the linear range of the two formats, where no difference in performance was observed.

Just Add Master Mix and Sample, and Begin Cycling
Ideal for projects such as validation of microarray and RNAi data, and pathway studies, the plates include just the right amount of TaqMan®Assay in each well: enough for one 20 µl reaction. You can order as few as three Gene Signature Plates, making these an affordable option for many laboratories and minimizing the waste of unused individually purchased TaqMan®Assays. Save a significant amount of time setting up your experiments. Just add master mix and sample, and begin cycling.

Figure 2 is an example Plate Layout with Gene Symbols and Assay IDs

Plate Map Ensures Proper Data Labeling and Easy Re-Ordering
Each pack of TaqMan® Array Plates is shipped with a CD containing the plate configuration map (see Figure 2) along with the details of each TaqMan®Assay. This information is imported into the real-time PCR instrument to enable proper labeling of experimental data and easy access to Assay ID numbers for simple reordering.

Simple to Use
Each TaqMan® Array Plate well contains a single TaqMan®Assay for one 20 µl reaction. The plates can be stored at room temperature or at 4°C. When you are ready to run your assays, simply add PCR master mix and your cDNA sample, seal the plate, and begin cycling on a real-time PCR instrument.

Compatibility
TaqMan® Array Plates have been optimized for use with TaqMan® Gene Expression Master Mix, but are also compatible with TaqMan® Universal PCR Master Mix. For studies using cultured cells, TaqMan® Array Plates are also compatible (and recommended) with the TaqMan® Gene Expression Cells-to-Ct™ Kit. TaqMan® Array Plates must be run on a real-time PCR instrument with 96-well plate capability. The plates have been validated for use on Applied Biosystems® 7000, 7300, 7500 and 7900HT Fast Real-Time PCR Systems using standard 96-well blocks, standard PCR cycling conditions, and 20 µl reaction volumes.

TaqMan™ Array, Human Transcription of mRNA, Fast 96-well Applied Biosystems™

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human Transcription of mRNA 96-well Plate contains 44 assays to transcription of mRNA associated genes and 4 assays to candidate endogenous control genes. All assays are plated in duplicate.

TaqMan™ Array Human Angiogenesis

The Applied Biosystems® TaqMan® Array Human Angiogenesis 96-well Plate contains 92 assays to angiogenesis and lymphangiogenesis associated genes and 4 assays to candidate endogenous control genes.

The panel of assays in this plate targets known angiogenesis growth factors like VEGF as well as matrix derived inhibitors such as endostatin. Additionally, the panel contains markers and targets for angiogenesis and lymphangiogenesis. Gene Signature Plates are 96-well plates that are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment.

• Affordable; minimum order of three plates; ideal for small, medium or large-sized projects
• Fast delivery; on your bench in days
• Convenient; dried PCR primer and TaqMan® probe sets supplied in a 96- well plate; just add master mix and your sample
• Same TaqMan®Assay Quality, New Format

TaqMan® Array Plates contain the same high quality TaqMan® Gene Expression Assays (PCR primers and TaqMan® probe sets) that have been commercially available for years in a convenient, dried, 96-well format. Extensive tests have found no difference in performance between TaqMan®Assays supplied in the traditional liquid format and assays dried into a TaqMan® Array Plate. Figure 1 shows the results of an experiment comparing the linear range of the two formats, where no difference in performance was observed.

Just Add Master Mix and Sample, and Begin Cycling
Ideal for projects such as validation of microarray and RNAi data, and pathway studies, the plates include just the right amount of TaqMan®Assay in each well: enough for one 20 µl reaction. You can order as few as three Gene Signature Plates, making these an affordable option for many laboratories and minimizing the waste of unused individually purchased TaqMan®Assays. Save a significant amount of time setting up your experiments. Just add master mix and sample, and begin cycling.

Figure 2 is an example Plate Layout with Gene Symbols and Assay IDs

Plate Map Ensures Proper Data Labeling and Easy Re-Ordering
Each pack of TaqMan® Array Plates is shipped with a CD containing the plate configuration map (see Figure 2) along with the details of each TaqMan®Assay. This information is imported into the real-time PCR instrument to enable proper labeling of experimental data and easy access to Assay ID numbers for simple reordering.

Simple to Use
Each TaqMan® Array Plate well contains a single TaqMan®Assay for one 20 µl reaction. The plates can be stored at room temperature or at 4°C. When you are ready to run your assays, simply add PCR master mix and your cDNA sample, seal the plate, and begin cycling on a real-time PCR instrument.

Compatibility
TaqMan® Array Plates have been optimized for use with TaqMan® Gene Expression Master Mix, but are also compatible with TaqMan® Universal PCR Master Mix. For studies using cultured cells, TaqMan® Array Plates are also compatible (and recommended) with the TaqMan® Gene Expression Cells-to-Ct™ Kit. TaqMan® Array Plates must be run on a real-time PCR instrument with 96-well plate capability. The plates have been validated for use on Applied Biosystems® 7000, 7300, 7500 and 7900HT Fast Real-Time PCR Systems using standard 96-well blocks, standard PCR cycling conditions, and 20 µl reaction

TaqMan™ Array Human Hematopoiesis Applied Biosystems™

The Applied Biosystems® TaqMan® Array Human Hematopoiesis 96-well Plate contains 92 assays to hematopoiesis associated genes and 4 assays to candidate endogenous control genes.

The panel of assays in the TaqMan® Array Human Hematopoiesis 96-well Plate targets genes involved in this process such as blood cell lineage-specific markers, cytokines, signaling molecules and regulators. Gene Signature Plates are 96-well plates that are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment.

• Affordable; minimum order of three plates; ideal for small, medium or large-sized projects
• Fast delivery; on your bench in days
• Convenient; dried PCR primer and TaqMan® probe sets supplied in a 96- well plate; just add master mix and your sample
• Same TaqMan®Assay Quality, New Format

TaqMan® Array Plates contain the same high quality TaqMan® Gene Expression Assays (PCR primers and TaqMan® probe sets) that have been commercially available for years in a convenient, dried, 96-well format. Extensive tests have found no difference in performance between TaqMan®Assays supplied in the traditional liquid format and assays dried into a TaqMan® Array Plate. Figure 1 shows the results of an experiment comparing the linear range of the two formats, where no difference in performance was observed.

Just Add Master Mix and Sample, and Begin Cycling
Ideal for projects such as validation of microarray and RNAi data, and pathway studies, the plates include just the right amount of TaqMan®Assay in each well: enough for one 20 µl reaction. You can order as few as three Gene Signature Plates, making these an affordable option for many laboratories and minimizing the waste of unused individually purchased TaqMan®Assays. Save a significant amount of time setting up your experiments. Just add master mix and sample, and begin cycling.

Figure 2 is an example Plate Layout with Gene Symbols and Assay IDs

Plate Map Ensures Proper Data Labeling and Easy Re-Ordering
Each pack of TaqMan® Array Plates is shipped with a CD containing the plate configuration map (see Figure 2) along with the details of each TaqMan®Assay. This information is imported into the real-time PCR instrument to enable proper labeling of experimental data and easy access to Assay ID numbers for simple reordering.

Simple to Use
Each TaqMan® Array Plate well contains a single TaqMan®Assay for one 20 µl reaction. The plates can be stored at room temperature or at 4°C. When you are ready to run your assays, simply add PCR master mix and your cDNA sample, seal the plate, and begin cycling on a real-time PCR instrument.

Compatibility
TaqMan® Array Plates have been optimized for use with TaqMan® Gene Expression Master Mix, but are also compatible with TaqMan® Universal PCR Master Mix. For studies using cultured cells, TaqMan® Array Plates are also compatible (and recommended) with the TaqMan® Gene Expression Cells-to-Ct™ Kit. TaqMan® Array Plates must be run on a real-time PCR instrument with 96-well plate capability. The plates have been validated for use on Applied Biosystems® 7000, 7300, 7500 and 7900HT Fast Real-Time PCR Systems using standard 96-well blocks, standard PCR cycling conditions, and 20 µl reaction volumes.

TaqMan™ OpenArray™ Human Stem Cell Panel, QuantStudio™ 12K Flex Applied Biosystems™

The TaqMan® OpenArray® Human Stem Cell Panel is an efficient, easy-to-use OpenArray® plate for the characterization of undifferentiated stem cells or their differentiated derivatives. This gene signature panel targets 609 well-defined genes validated as markers for pluripotency, plus 22 endogenous control genes. The format of the OpenArray® plate allows for 1–4 replicates to be run in parallel per plate.

The TaqMan® OpenArray® Human Stem Cell Panel contains a well-defined set of validated gene expression markers to characterize human embryonic stem (ES) cell identity and assess phenotypic variations between embryonic stem cell isolates. The gene content of this OpenArray® plate resulted directly from the work of the I.S.C.I consortium and characterization of human embryonic stem cell lines by the International Stem Cell Initiative.

The plate is pre-formatted and inventoried, cost-effective, convenient, and easy-to-use, without the need for expensive robotics. Results are reproducible and consistent across samples, studies, and labs—for the same data quality from plate-to-plate and lot-to-lot, even with different operators.

The Right Targets
This OpenArray® plate uses the proprietary Applied Biosystems® OpenArray® technology to simultaneously analyze gene expression levels by quantitative PCR for 609 test genes and 22 endogenous controls.

Genes were included based on the following criteria:

• Expression in human embryonal carcinoma cells (hEC), primordial germ cells, or human ES (hES) cells
• Known role in maintenance of pluripotency in hES cells
• Identification in microplate-based experiments as being correlated with the stem cell state
• Expression known to be characteristic of specific differentiation lineages in the post implantation embryo and mature tissues

This panel is intended for use with the QuantStudio™ 12K Flex Real-time PCR system which can cycle and image 4 pates simultaneously, providing high-throughput results with ease.

Human Alzheimer's Array Applied Biosystems™

Two TaqMan® Alzheimer’s Arrays are available; one for human and one for mouse. The mouse assays closely follow the human panel and are from orthologous genes of the human assays. The human panel contains 94 test assays and two endogenous controls (18S and HPRT1). The mouse panel has 92 assays and four controls (18S, actb, hprt1 and ipo8).

• Pre-formatted and inventoried — each card contains a select group of TaqMan® Gene
• Expression Assays pre-configured in a micro fluidic array, ready to ship to you
• Cost-effective — TaqMan® Arrays are available in economical four-card packages that enable you to simplify your workflow without breaking your budget
• Convenient and easy to use — get the performance you’ve come to expect from TaqMan® Gene Expression Assays without needing expensive robotics
• Reproducible results — get consistent, reliable data across samples, studies, and labs—the same data quality from card-to-card and lot-to-lot — even with different operators

The Right Targets
TaqMan® Gene Expression Assays for the Alzheimer’s TaqMan® Array were based on the 'amyloid hypothesis’. We selected genes involved in APP processing that generate Aβ and included genes implicated in multiple secondary steps of Aβ aggregation, tau hyperphosphorylation, excitotoxicity, inflammation, oxidation and microglial activation. We also added assays for genes involved in cholesterol biosynthesis because of the correlation between high cholesterol and increased risk of AD3. Numerous reports of genes associated with AD pathology, biochemistry and genetics are also included.

Easy to Load and Run
Using the TaqMan® array is fast and simple. The micro fluidic technology uses 8 sample-loading ports, each connected to 48 reaction wells. Simply pipette your sample (pre-mixed with TaqMan® Universal PCR Master Mix) into each sample-loading port and briefly centrifuge. Within minutes, your 384-well TaqMan® array is ready to run on the 7900HT Fast Real-Time PCR System.

Ideal Screening Technology
TaqMan® Arrays are ideal for researchers' screening applications, from biomarker and toxicology screens to pathway and disease-set analysis. These arrays are part of a collection of TaqMan® Arrays that enable analysis of hundreds of TaqMan® Gene Expression Assays on an array with minimal effort. TaqMan® Gene Expression Assays are preloaded so you can standardize samples and laboratory sites while maintaining reproducibility, accuracy, and sensitivity.

TaqMan™ Array Respiratory Tract Microbiota Comprehensive Card Applied Biosystems™

TaqMan® Array Respiratory Tract Microbiota Comprehensive Card is an efficient, easy-to-use TaqMan Array Card (48-assay format) for the characterization of key respiratory tract microbial targets through real-time PCR. This card contains TaqMan Microbial Assays for 41 microbial targets, plus Universal Extraction Organism Control (B. atropheus), Universal DNA Spike-In Positive Control (Xeno), 18s control and human RNase P RPPH1 control. Each TaqMan Array Card can be used for running 7 samples and 1 control sample.

Key Feature of TaqMan® Array Cards:
• Pre-formatted and inventoried—each card contains a select group of TaqMan® Microbial Assays pre-configured in a micro fluidic array, ready to ship to you
• Convenient and easy to use—get the performance you’ve come to expect from TaqMan® Microbial Assays without the need for expensive robotics
• Reproducible results—get consistent, reliable data across samples, studies, and labs—the same high data quality from card-to-card and lot-to-lot—even with different operators

TaqMan™ Array, Human Chemokines, Fast 96-well Applied Biosystems™

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The panel of assays in the TaqMan® Array 96-well Human Chemokines Plate targets genes from each of the four classes of chemokines: 1) CC Chemokines, 2) CXC Chemokines, 3) C Chemokines, and 4) CX3C Chemokines. Other chemokine related genes, including chemokine ligands and receptors, are also included in this panel.

TaqMan™ Array Human BRCA1 Pathway Applied Biosystems™

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human BRCA1 Pathway 96-well Plate contains 44 assays to genes associated with the BRCA1 pathway and 4 assays to candidate endogenous control genes. All assays are plated in duplicate.

TaqMan™ Array, Human Angiogenesis, Fast 96-well Applied Biosystems™

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The panel of assays in the TaqMan® Array 96-well Human Angiogenesis Plate targets known angiogenesis growth factors like VEGF as well as matrix derived inhibitors such as endostatin. Additionally, the panel contains markers and targets for angiogenesis and lymphangiogenesis.

TaqMan™ Array Human PI3K Signaling Applied Biosystems™

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human PI3K Signaling 96-well Plate contains 92 assays to genes associated with PI3K signaling and 4 assays to candidate endogenous control genes.
Results per page
    spinner