Shop All Buffers and Standards

Dilution


HBSS, no calcium, no magnesium, no phenol red Gibco™

Hanks' Balanced Salt Solution (HBSS) is used for a variety of cell culture applications, such as washing cells before dissociation, transporting cells or tissue samples, diluting cells for counting, and preparing reagents. Formulations without calcium and magnesium are required for rinsing chelators from the culture before cell dissociation.

We offer a variety of Gibco® HBSS formulations for a range of cell culture applications.

This HBSS is modified as follows:

WithWithout
• Glucose• Calcium
• Magnesium
• Phenol Red

The complete formulation is available.

cGMP Manufacturing and Quality System
Gibco® HBSS is manufactured at a cGMP compliant facility, located in Grand Island, New York. The facility is registered with the FDA as a medical device manufacturer and is certified to ISO 13485 standards. For supply chain continuity, we offer an identical Gibco® HBSS product made in our Scotland facility (14175-053). This facility is registered with the FDA as a medical device manufacturer and is certified to the ISO 13485 standard.

PBS, pH 7.4 Gibco™

PBS (phosphate buffered saline) is a balanced salt solution used for a variety of cell culture applications, such as washing cells before dissociation, transporting cells or tissue, diluting cells for counting, and preparing reagents. PBS is formulated without calcium and magnesium for rinsing chelators from the culture before cell dissociation. We offer a variety of PBS formulations for a range of cell culture applications. Find the right formulation using the media selector tool.

This PBS is manufactured as follows:
Without
• Calcium
• Magnesium
• Phenol Red

The complete formulation is available.

cGMP manufacturing and quality system
PBS is manufactured at a cGMP-compliant facility located in Paisley, Scotland, UK. The facility is registered with the FDA as a medical device manufacturer and is certified to the ISO 13485 standard. For supply chain continuity, we offer an identical PBS product made in our Grand Island facility (10010015). This facility is also registered with the FDA as a medical device manufacturer and certified to the ISO 13485 standards.

Orion™ ISE Calibration Standards Thermo Scientific™

Take reproducible ISE measurements with Thermo Scientific™ Orion™ ISE Calibration Standards. For use with ion selective electrodes from ammonia to water hardness.

ProcartaPlex™ Wash Buffer (10X) Invitrogen™

The ProcartaPlex Wash Buffer (10X) is developed for use with the ProcartaPlex assays. The ProcartaPlex Wash Buffer is supplied as a 10X concentrate and is used for washing the ProcartaPlex Assays using Flat Bottom Plates. It is a simple mix of buffers, salts, and mild detergent.
The ProcartaPlex Wash Buffer (10X) is included in our basic kits and off the shelf panels. Additionally, we offer the ProcartaPlex Wash Buffer (10X) as a stand-alone item.

Reported Application
Multiplex Immunoassay

COD (Chemical Oxygen Demand) Calibration Standards for AQUAfast Colorimeters Thermo Scientific™

COD (Chemical Oxygen Demand) Calibration Standards are for use with Orion™ AQUAfast Colorimeters such as AQ4000 Advanced Colorimeter and Orion AQUAfast II AQ2040 Colorimeter.COD Chemistries can be measured by these colorimeters and ideal for environmental and wastewater monitoring. The calibration standards are used to check operations prior to using the instruments.

Orion™ ORP Standards for Redox/ORP Electrodes Thermo Scientific™

Measure ORP simply and accurately with Thermo Scientific™ Orion™ ORP Standards for Redox/ORP Electrodes. Orion OPR standards are stable for up to a year (unopened) and can be used directly from the bottle with no mixing or diluting.

HBSS, calcium, magnesium, no phenol red Gibco™

Hanks' Balanced Salt Solution (HBSS) is used for a variety of cell culture applications, such as washing cells before dissociation, transporting cells or tissue samples, diluting cells for counting, and preparing reagents. Formulations with calcium and magnesium are generally used as transport media, or for reagent preparation.

We offer a variety of Gibco® HBSS formulations for a range of cell culture applications.

This HBSS is modified as follows:

WithWithout
• Calcium• Phenol Red
• Magnesium• Sodium Pyruvate
• Glucose

The complete formulation is available.

cGMP Manufacturing and Quality System
Gibco® HBSS is manufactured at a cGMP compliant facility, located in Grand Island, New York. The facility is registered with the FDA as a medical device manufacturer and is certified to ISO 13485 standards. For supply chain continuity, we offer an identical Gibco® HBSS product made in our Scotland facility (14065-049). This facility is registered with the FDA as a medical device manufacturer and is certified to the ISO 13485 standard.

HBSS, no calcium, no magnesium Gibco™

Hanks' Balanced Salt Solution (HBSS) is used for a variety of cell culture applications, such as washing cells before dissociation, transporting cells or tissue samples, diluting cells for counting, and preparing reagents. Formulations without calcium and magnesium are required for rinsing chelators from the culture before cell dissociation.

We offer a variety of Gibco® HBSS formulations for a range of cell culture applications.

This HBSS is modified as follows:

WithWithout
• Phenol Red• Calcium
• Glucose• Magnesium

The complete formulation is available.

cGMP Manufacturing and Quality System
Gibco® HBSS is manufactured at a cGMP compliant facility, located in Grand Island, New York. The facility is registered with the FDA as a medical device manufacturer and is certified to ISO 13485 standards. For supply chain continuity, we offer an identical Gibco® HBSS product made in our Scotland facility (14170-138). This facility is registered with the FDA as a medical device manufacturer and is certified to the ISO 13485 standard.

Orion™ Pure Water™ pH Buffers and pHISA™ Adjustor Thermo Scientific™

Sample well water, rain water, distilled/deionized water, boiler feed water, process water and more with the Thermo Scientific™ Orion™ Pure Water™ pH Buffers and pHISA™ Adjustor. It offers fast, accurate pH results in high purity and low ionic strength waters.

Premix Buffer Concentrate, 100 mL Applied Biosystems™

This reagent is intended for N-terminal protein sequencing applications.

For Research Use Only. Not for use in diagnostics procedures.

Internal Standards/Basic Hydride Generation Kit for the iCAP™ 7000 Series ICP-OES system Thermo Scientific™

Achieve regulatory compliance for the ICP-OES analysis of toxic hydride-forming elements Arsenic, Bismuth, Antimony, Selenium and Mercury in environmental, biological, pharmaceutical and food samples. With the simple addition of this Thermo Scientific™ Internal Standards/Basic Hydride Generation Kit for the Thermo Scientific™ iCAP™ 7000 Plus Series ICP-OES system, the detection range of the analyzer can be lowered to sub-ppb levels for hydride-forming elements.

Torch Holder Assembly Spares for the EMT plasma torch for the iCAP™ 7000 Series ICP-OES System Thermo Scientific™

Keep your ICP-OES analyzer in top condition; use only dedicated spares and Thermo Scientific™ Consumables, including Thermo Scientific™ Torch Holder Assembly Spares for the EMT plasma torch for Thermo Scientific™ iCAP™ 7000 Plus Series ICP-OES system. Simple routine maintenance is enabled through the unique design of the Thermo Scientific™ Enhanced Matrix Tolerance (EMT) plasma torch, just clip the torch in and out in seconds.

DPBS, no calcium, no magnesium Gibco™

Dulbecco's phosphate-buffered saline (DPBS) is a balanced salt solution used for a variety of cell culture applications, such as washing cells before dissociation, transporting cells or tissue samples, diluting cells for counting, and preparing reagents. Formulations without calcium and magnesium are required for rinsing chelators from the culture before cell dissociation.

We offer a variety of Gibco® DPBS formulations for a range of cell culture applications.

This DPBS is modified as follows:

Without
• Calcium
• Magnesium
• Phenol Red

The complete formulation is available.

cGMP Manufacturing and Quality System
Gibco® DPBS is manufactured at a cGMP compliant facility, located in Grand Island, New York. The facility is registered with the FDA as a medical device manufacturer and is certified to ISO 13485 standards. For supply chain continuity, we offer an identical Gibco® DPBS product made in our Scotland facility (14190-240). This facility is registered with the FDA as a medical device manufacturer and is certified to the ISO 13485 standard.

Qdot™ Incubation Buffer Invitrogen™

Qdot® Incubation Buffer - 2% BSA in 50 mM borate buffer, pH 8.3, containing 0.05% sodium azide is dentical to the incubation buffer (component B) provided in the Qdot® ITK™ Streptavidin Conjugate Kits.

eBioscience™ Binding Buffer for Annexin V Invitrogen™

Binding Buffer for Annexin V Apoptosis detection Kit

Reactivity/Species
Human, Mouse, Rat

Reported Application
Flow Cytometric Analysis

Results per page
    spinner