Controls, panels, dilution matrices, reagents, and other supplies designed for clinical analysis procedures that test bodily fluids for specific analytes. Available in multiple quantities and suited for testing of plasma, serum, whole blood, urine, CSF, etc.
Prepare specimens for testing in plasma-based nucleic acid assays with the Thermo Scientific™ AcroMetrix™ EDTA Plasma Dilution Matrix (RUO). This matrix is a human plasma matrix shown to be non-reactive for blood borne pathogens, viral nucleic acids and serological markers.
Monitor the performance of total, conjugated, unconjugated and neonatal Bilirubin with tri-level, assayed Thermo Scientific™ MAS™ Bilirubin Controls. These controls are also available in a convenient Vista™ vial format.
Monitor the performance of quantitative and manual chemical analysis of human cerebrospinal fluid with Thermo Scientific™ MAS™ Cerebrospinal Fluid Control, a bi-level control assayed for major instrument systems as well as for cellulose acetate and agarose gel electrophoresis.
Monitor immunoassay screening procedures with liquid, ready-to-use Thermo Scientific™ MAS™ DOA TOTAL Controls. These are multi-constituent urine toxicology controls, offering 19 analytes with four distinct levels at drug concentrations 25% below and above commonly used screening and SAMHSA cutoffs.
Monitor the performance of various cancer antigen tests on automated instruments with liquid assayed, multi-analyte Thermo Scientific™ MAS™ T-Marker Controls. In compliance with NACB and EGTM* guidelines, MAS T-Marker Quality Controls allow for independent evaluation of test performance in your lab.
Validate and assess run-to-run solid tumor assay variation. Intended for use with next generation sequencing (NGS), qualitative and quantitative PCR research assays that are designed to identify fusions, CNVs, SNVs and indels. For research use only.
Monitor the performance of various serum protein and serology test procedures with ready-to-use, liquid assayed multi-analyte Thermo Scientific™ MAS™ Immunology Controls. These controls are also available in a convenient Vista™ vial format.
The Fetal Hemoglobin (HbF) Test is based on a monoclonal antibody directed to fetal hemoglobin (hemoglobin F). This antibody is conjugated with fluorescein (FITC).
Identify increases in random or systematic error of nucleic acid test procedures for the quantitative and qualitative determination of hepatitis B viral DNA (HBV DNA) with the Thermo Scientific™ AcroMetrix™ HBV Controls.
Assess the analytical performance of molecular test procedures designed to identify different genetic variants (genotypes) of human Hepatitis C Virus (HCV) with the Thermo Scientific™ AcroMetrix™ HCV Genotyping Panel (RUO).
Monitor the performance of assays that detect antibodies to hepatitis B surface antigen (anti-HBs) over long periods of time with the Thermo Scientific™ AcroMetrix Anti-HBs Control (RUO), a low positive control.
Assess the performance of nucleic acid test procedures for the qualitative determination of human papillomavirus DNA (HPV DNA) with the Thermo Scientific™ AcroMetrix™ HPV Controls (RUO). Routine use of external run controls enables laboratories to monitor day-to-day test variation, lot-to-lot...
Assess molecular test procedures, including the DNA extraction step, for the qualitative and quantitative determination of enterovirus RNA with the Thermo Scientific™ AcroMetrix™ EV Controls (RUO). The controls are for Research Use Only and are not for use in diagnostic procedures.
Assess the analytical performance of molecular test procedures, including the nucleic acid extraction step, for the quantitative and qualitative determination of viruses related to transplant disease with the Thermo Scientific™ AcroMetrix™ Transplant Virus Panels (RUO).
Estimate the precision and reproducibility of procedures for the detection of hepatitis B surface antigen (HBsAg), antibodies to hepatitis C virus (anti-HCV), antibodies to human immunodeficiency virus types 1 and 2 (anti-HIV-1/2), and antibodies to hepatitis B core antigen (anti-HBc) in diagnostic...
Validate and assess run-to-run assay variation of ctDNA somatic mutation panels. Intended for use with next generation sequencing (NGS), qualitative/quantitative PCR assays designed to identify somatic mutations in DNA from liquid biopsy samples. For research use only.
Identify increases in random or systematic error of nucleic acid test procedures for the quantitative and qualitative determination of human cytomegalovirus (CMV) DNA with the Thermo Scientific™ AcroMetrix™ CMV Controls (RUO).
Detect interfering substances that may inhibition nucleic acid amplification or serology assays with the Thermo Scientific™ AcroMetrix Inhibition Panel (RUO). Designed to mimic clinical conditions such as haemolysis, icterus and lipemia, this panel contains interfering substances found in serum,...
Identify increases in random or systematic error of nucleic acid test procedures for the quantitative and qualitative determination of Adenovirus DNA with the Thermo Scientific™ AcroMetrix™ Adenovirus Controls (RUO).
Assess molecular diagnostic procedures, including the DNA extraction step, for the qualitative and quantitative determination of enterovirus RNA with the Thermo Scientific™ AcroMetrix™ EV Controls. The controls are for In Vitro Diagnostic Use.
Estimate the precision and reproducibility of NAT assays that are designed to detect viral nucleic acids in human plasma from donations of whole blood and blood components for transfusion with the Thermo Scientific™ AcroMetrix NAT Blood Screening Controls.
Assess the analytical performance of molecular diagnostic test procedures for the qualitative determination of viral nucleic acids with the Thermo Scientific™ AcroMetrix™ Controls. These controls are intended for use with the detection of viral nucleic acids from donations of whole blood and blood...
Assess the performance of nucleic acid test procedures for the qualitative determination of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) nucleic acids in swab and urine patient specimens with Thermo Scientific™ AcroMetrix™ CT/NG Control.
Assess the performance of molecular assays that detect human immunodeficiency virus type 1, Hepatitis C and Hepatitis B in patient samples with the Thermo Scientific™ AcroMetrix™ HIV-1/HCV/HBV Controls (IVD).
Monitor alcohol and/or ammonia in human serum with bi-level, assayed liquid Thermo Scientific™ MAS™ Alcohol and Ammonia Controls. Available in a convenient Vista™ vial format, this ready-to-use product is packed in convenient multipacks.
Simplify the process of quality control during urinalysis testing with room-temperature, stable Thermo Scientific™ MAS™ UA DipTube Control. This liquid assayed urinalysis control for procedures used in routine urinalysis testing is conveniently-packed to afford immediate time and cost savings.
Qualify operators and assess performance of molecular diagnostic test procedures that detect Human Immunodeficiency virus RNA, Hepatitis B DNA and Hepatitis C RNA in donor blood samples with the Thermo Scientific™ AcroMetrix™ PeliSpy NAT MM 375 Reagent.
Estimate the precision and reproducibility of procedures for the detection of hepatitis B surface antigen (HBsAg), antibodies to hepatitis B core antigen (anti-HBc), antibodies to hepatitis C virus (anti-HCV), antibodies to human immunodeficiency virus type 1 group M and O (anti-HIV-1 group M and...
As oncology testing expands, laboratories are challenged with finding highly characterized, standardized and reproducible quality control materials to support validation or verification of new assays.AcroMetrix control products for oncology testing aid laboratories in meeting quality and regulatory...
Per regulatory guidelines, therapies manufactured using cell culture must be proven free of mycoplasma contamination. To be compliant, manufacturers have traditionally outsourced testing to labs that specialize in the 28-day culture-based test method.