Petroleum, Natural Gas & Refinery Testing

On this page:

From upstream extraction to downstream refining

Chemical analysis is vital to ensure quality, safety, and efficiency across the oil and gas supply chain. Modern workflows encompass diverse matrices, spanning raw crude oil and natural gas to refined distillates and industrial process water. Thermo Fisher Scientific provides tailored analytical solutions to monitor variations in energy content, detect corrosive impurities, and protect downstream assets while helping laboratories comply with regulations and standards.


Raw material characterization

Detecting and identifying organic and inorganic impurities in raw materials is necessary not only to optimize process methods, but also to help guard against downtime and major unexpected maintenance. Crude oil or natural gas composition may vary depending on source, extraction methods, and other variables. This stage covers:

  • Crude oil qualification
  • Organic or inorganic contaminants analysis
  • Isotope characterization
Application Sample type Selected standards Technique & recommended solution
Crude oil qualification – characterize crude oil and potential impurities
  • Crude oil
  • ASTM D5307
  • ASTM D7169
  • IP 545
  • EN 15199-3
  • ASTM D7691
Inorganic contaminants analysis – trace raw materials and critical inorganic contaminants (from % to ppb)
  • Naphtha
  • Condensates
  • LPG
  • ASTM D7111
  • ASTM D7691
  • UOP 391
  • UOP 779
  • UOP 991
  • ASTM D5623
  • ASTM D6667
  • ASTM D7994
  • ASTM D7423
  • ASTM D7754

Organic contaminants analysis – trace raw materials and critical organic contaminants (from % to ppb)

  • Feedstocks
  • NGA & NGL
  • Heavy ends
  • ASTM 5623
  • UOP 791
  • ASTM D7754
  • ASTM D7423
  • ASTM D5443
  • ASTM D6730
  • ASTM D5580
  • ASTM D6591
Isotope characterization – assure reliable and safe supply of product
  • Natural gas
  • Crude oil

NA


In-process sampling and refinery water analysis

Advanced automation and controls help enhance plant efficiency, safety, and profitability while supporting efforts to reduce emissions. Across every unit, precise flow monitoring, material characterization, and contaminant analysis provide engineers with valuable insights to help stabilize processes and improve uptime.

 

This phase also includes safeguarding refinery equipment and the environment through stringent water process management. This encompasses the use, treatment, and analysis of cooling water and aqueous amine scrubber solutions used to neutralize and remove acid gases—such as carbon dioxide (CO2) and hydrogen sulfide (H2S)—from the process stream to help mitigate corrosion and reduce the potential for environmental release.

 

This stage covers:

  • Flow measurements and materials characterization
  • Process stream contaminant analysis
  • Scrubber solution and alkanolamine tracking
  • Industrial wastewater and cooling water monitoring
Application Sample type Selected standards Technique & recommended solution

Flow measurement – monitor process with flowmeter and supervision systems

  • Natural gas
  • Natural Gas Liquids (NGL)
  • Feedstock and Feed Gas Streams
  • Flare gas
  • High purity gases

N/A

Contaminant analysis – analyze critical contaminants during production

  • Process streams
  • Catalysts

N/A

Process & refinery water analysis – Monitor amines, anions, metals, and organic acids to help protect infrastructure and support compliance with environmental regulations

  • Wastewater
  • Cooling water
  • Scrubber solutions
  • EPA 300
  • EPA 300.1
  • EPA 8260
  • EPA 8270
  • EPA 524.4
  • EPA 624
  • ASTM D4327

Material characterization – avoid unexpected downtime and verify material ID

  • Coke
  • Catalysts
  • Pipe metal

N/A


Product analysis for quality and certification

Detailed analysis of liquid or gas components helps characterize the composition of refinery products. Accurate and precise analysis of product streams supports quality assurance and can provide data to demonstrate conformity with contractual requirements. A robust data management system can support alignment with industry and local certification requirements while helping maintain traceability in the event of a regulatory audit. This stage includes:

  • Certificate of Analysis (CoA) / Certificate of Conformity (CoC)
  • Detailed liquid hydrocarbon or gaseous composition
  • Traceability and data management
Application Sample type Selected standards Technique & recommended solution

Certificate of analysis / certificate of conformity – deliver correct documentation to customers

  • Gasoline
  • Diesel
  • Jet fuel
  • LPG
  • NGA/NGL
  • ASTM D4815
  • ASTM D5580
  • ASTM D3606
  • ASTM D975
  • ASTM D1655
  • DEF-STAN 91-091
  • ASTM D2163
  • GPA 2261
  • ISO 6974
  • ASTM D1945

Detailed liquid composition – provide a detailed molecular analysis on liquid fuels and lubricants

  • Gasoline
  • Biofuels
  • Lube oil
  • ASTM D6730
  • ASTM D5134
  • ASTM D6729
  • ASTM D5580
  • ASTM D5599
  • ASTM D5134
  • ASTM D6839
  • ASTM D6293
  • ASTM D6584
  • ASTM D6730
  • ASTM D2425
  • ASTM D6379
  • ASTM D5185
  • ASTM D4951
  • ASTM D7359

Detailed gaseous composition – provide a detailed analysis of gaseous and gas-liquid products

  • Natural gas
  • LPG
  • NGL
  • GPA 2261 (natural gas)
  • GPA 2177 (natural gas liquid)
  • ASTM D1945
  • ASTM D7833
  • ASTM D2163
  • ASTM D2598
  • ASTM D2712

Traceability – Support alignment with your quality management system and applicable regulatory requirements through robust data management systems

  • All final products
  • ISO17025

Learning center: oil & gas testing

Learn about testing petroleum and natural according to different analytical methods, such as ASTM and GPA methods.

GC Analyzers overview: solutions across hydrocarbon processing

Thermo Fisher Scientific offers analytical solutions designed to support a wide range of refinery operations and requirements, including gas chromatography.

Infographic: consolidated industrial water and wastewater analysis

Explore the water analysis process, which is vital to eliminate corrosion and scaling in industrial components.

Discover CDS solutions for petrochemical workflows

When productivity and cost efficiency are key to successful lab operation, you can benefit from a single, centralized software system tailored to the petrochemical industry.

Blog: Analyte Guru

Browse industry news and discussion collected by our technical experts.

Power of collaborative expertise

Explore complete analytical testing workflows across petroleum, natural gas, and industrial water processes.


Frequently asked questions

Refinery wastewater testing typically includes screening for contaminants that can affect discharge quality, treatment performance, equipment integrity, and environmental risk. Common parameters include oil and grease, total organic carbon, COD/BOD, ammonia, sulfide, phenols, volatile organic compounds, semi-volatile organic compounds, anions, organic acids, and trace metals. EPA petroleum refining effluent guidelines are defined under 40 CFR Part 419, which addresses wastewater discharges from petroleum refineries.

A robust refinery wastewater monitoring program may combine ion chromatography or HPIC for anions and organic acids, ICP-OES or ICP-MS for metals, GC-MS for VOCs/SVOCs, discrete analysis for wet chemistry parameters, and sample preparation technologies such as accelerated solvent extraction. Common method families include EPA 300 and EPA 300.1 for anions by ion chromatography, EPA 8260 and EPA 524.4 for volatile organic compounds, EPA 8270 for semi-volatile organic compounds, and EPA 624 for purgeable organics. Depending on the target analytes, laboratories may use HPIC/IC, GC-MS, ICP-OES, ICP-MS, discrete analyzers, and solvent extraction workflows to support wastewater monitoring, process control, and discharge documentation.

In amine treating, sour gas treatment, and acid gas removal workflows, laboratories typically monitor the chemistry of the amine solution to understand solvent health, corrosion risk, and treatment efficiency. Important measurements include amine concentration, heat-stable salts, degradation products, organic acids, chloride, sulfate, thiosulfate, metals, and other ionic contaminants.

 

These measurements help operators identify when the amine system is losing efficiency or becoming more corrosive. In gas treating, amine scrubber solutions are used to remove CO₂ and H₂S from process streams; if degradation products and heat-stable salts build up, the solution can contribute to corrosion, foaming, poor acid gas removal, and higher solvent reclaiming costs.

Water chemistry testing helps refineries detect conditions that lead to corrosion, scaling, fouling, pitting, stress-corrosion cracking, heat exchanger efficiency loss, and unplanned maintenance. In refinery systems, even low-level contaminants such as chloride, sulfate, organic acids, sulfide, ammonia, dissolved metals, and hardness-related ions can contribute to asset degradation when they are not controlled.

 

Routine testing of cooling water, boiler water, wastewater, sour water, and amine scrubber solutions allows teams to adjust treatment chemicals, identify process leaks, monitor contaminant ingress, and verify that water treatment units are operating correctly.

Natural gas BTU analysis and pipeline gas quality testing are typically performed using gas chromatography. The analysis measures the hydrocarbon composition of natural gas such as methane, ethane, propane, butanes, pentanes, and heavier hydrocarbons, along with non-hydrocarbon components such as nitrogen, carbon dioxide, oxygen, hydrogen sulfide, helium, and hydrogen, depending on the method and instrument configuration. The resulting composition data can be used to calculate heating value, BTU content, relative density, compressibility, Wobbe Index, and other parameters relevant to natural gas quality assessment.

Water dew point measures the temperature and pressure conditions at which water vapor condenses from natural gas. It is important because excess water can contribute to pipeline corrosion, hydrate formation, freezing, and operational problems.


Hydrocarbon dew point measures the conditions at which heavier hydrocarbons condense from the gas phase into liquid. This is important because hydrocarbon liquid dropout can affect pipeline operation, gas processing, compressor reliability, and product quality. Pipeline gas quality evaluations often consider HHV/BTU, H₂S, CO₂, nitrogen, oxygen, water dew point, and hydrocarbon dew point together when checking gas against tariff or contractual specifications.

Before running a new crude slate, refineries typically test for contaminants that can affect crude valuation, corrosion control, desalter performance, catalyst life, emissions, and downstream product quality. High-priority crude oil contaminants include sulfur, nitrogen, nickel, vanadium, iron, sodium, salts, chlorides, organic acids, water and sediment, mercury, arsenic, and other trace metals.


Metals such as nickel, vanadium, iron, and sodium are especially important because they can affect crude oil and residual fuel value, and nickel and vanadium can deactivate catalysts during processing. ASTM methods such as D5708 and D5863 address determination of these metals in crude oils and residual fuels.

Generating a Certificate of Analysis (CoA) may involve established analytical methods, controlled sample handling, instrument calibration, defined specifications, and documented data review. For fuels and hydrocarbon products, a CoA may include composition, sulfur, oxygenates, aromatics, boiling range, metals, density, calorific value, and other product-specific parameters, depending on the product and applicable requirements.

 

Analytical technologies used in these workflows may include GC and GC-MS for hydrocarbon composition and volatile impurities, ICP-OES or ICP-MS for elemental contaminants, LC for selected liquid fuel workflows, FTIR or UV-Vis for targeted product checks, and chromatography data systems or LIMS to support electronic record management and data traceability.

Our general purpose product lines, including LC-MS products, are not intended for in vitro diagnostic purposes in accordance with our product documentation, manuals, and labels. They are designated for General Laboratory Use Only.

 

Our general purpose product lines have not been tested or validated for such applications and their use for in vitro diagnostic purposes may result in health and safety risks. They are designated for Research Use Only Applications.

 

For Research Use Only - Not For Use In Diagnostic Procedures.