Click-iT™ Plus Alexa Fluor™ 488 Picolyl Azide Toolkit
Click-iT™ Plus Alexa Fluor™ 488 Picolyl Azide Toolkit
Invitrogen™

Click-iT™ Plus Alexa Fluor™ 488 Picolyl Azide Toolkit

Los kits de herramientas de azida picolil Alexa Fluor™ Click-iT™ Plus contienen todo lo que necesita para llevar a caboMás información
Have Questions?
Número de catálogoCantidad
C106411 kit
Número de catálogo C10641
Precio (MXN)
15,056.30
Each
Añadir al carro de la compra
Cantidad:
1 kit
Precio (MXN)
15,056.30
Each
Añadir al carro de la compra
Los kits de herramientas de azida picolil Alexa Fluor™ Click-iT™ Plus contienen todo lo que necesita para llevar a cabo reacciones clic catalizadas por cobre con compuestos sensibles al cobre, al tiempo que se conservan todos los beneficios de la reacción clic estándar de azida/alquino. Las azidas picolil reaccionan de forma eficaz con el cobre quelado, lo que permite minimizar el cobre libre en la reacción clic y crea una protección frente a las reacciones de cobre no deseadas con proteínas (por ejemplo, GFP, RPE), ácidos nucleicos (por ejemplo, ARN, oligos) e incluso moléculas pequeñas (por ejemplo, faloidina).

• Flexible: optimice su propia reacción Click–iT™ para la detección o etiquetado de cualquier biomolécula que contenga alquinos in vitro o en células y muestras de tejido
• Brillante y sensible: los colorantes fluorescentes superiores Alexa Fluor™ combinados con la eficacia de la azida picolil
• Práctico: contiene todos los tampones y reactivos necesarios para crear la reacción clic óptima

Cada kit de herramientas de azida picolil Click-iT™ Plus incluye 100 µg de colorante azida picolil Alexa Fluor™ y todos los reactivos necesarios para crear un cóctel de reacción con la concentración óptima de cobre y quelato para cualquier aplicación clic de etiquetado o detección basada en química. Las pautas para diseñar y optimizar la reacción clic de azida picolil/alquino que desee se proporcionan en el manual del producto. Además, la azida picolil Click-iT™ Plus ofrecen una mayor sensibilidad y tiempos de reacción más rápidos en comparación con las azidas estándar en condiciones de reacción idénticas.
Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Especificaciones
Tipo de etiquetaColorantes Alexa Fluor
Línea de productosClick-iT
Tipo de productoKit de herramientas de azida picolil 488
Cantidad1 kit
Etiqueta o tinteAlexa Fluor 488
Unit SizeEach
Contenido y almacenamiento
  • 1 x 100 μg de azida de colorante-picolilo Alexa Fluor™
  • 1 x 4 ml de tampón de reacción Click-iT™
  • 1 x 1,5 ml de sulfato de cobre (II)
  • 1 x 500 μl de protector de cobre
  • 1 aditivo de tampón Click-iT™
Cada k

Preguntas frecuentes

What is the excitation/emission maxima of the Alexa Fluor 488 dye?

Alexa Fluor 488 has fluorescence excitation and emission maxima of 495/519 nm.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

What are the main characteristics of a Click-iT reaction?

Click reactions have several general characteristics: the reaction is efficient, no extreme temperatures or solvents are required, the reaction is complete within 30 minutes, the components of the reaction are bio-inert, and perhaps most importantly, no side reactions occur-the label and detection tags react selectively and specifically with one another. This final point is a key advantage of this powerful detection technique; it is possible to apply click chemistry-labeled molecules to complex biological samples and detect them with unprecedented sensitivity due to the extremely low background of the reaction.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I will be performing a cell proliferation assay using Click-iT EdU kit. At what point can I stop overnight, or do I have to perform all the steps continuously?

One may store the sample after fixation overnight in PBS at 4oC. For longer storage (<1 week) , store in buffer with 1-2% formaldehyde or in formalin to limit microbial growth. If you use sodium azide as a microbial inhibitor, it must be completely removed prior to the Click-iT reaction.

Find additional tips, troubleshooting help, and resources within our Cell Viability, Proliferation, Cryopreservation, and Apoptosis Support Center.

Can I combine Click-iT or Click-iT Plus reactions with phalloidin conjugates used for actin staining?

We do not recommend using phalloidin conjugates for staining actin in combination with traditional Click-iT or Click-iT Plus reactions since phalloidin is extremely sensitive to the presence of copper.

For staining actin in combination with traditional Click-iT or Click-iT Plus reactions, we recommend using anti-α-actin antibodies for staining actin in the cytoskeleton. You can find a list of our actin antibodies here.

Another option would be to use the Click-iT Plus Alexa Fluor Picolyl Azide Toolkit (Cat. Nos. C10641, C10642, C10643). These Click-iT Plus toolkits provide Copper and Copper protectant separately which makes it easier to titrate the copper concentration to obtain optimal labeling with minimal copper-mediated damage. You may need to optimize the click reaction with the lowest possible concentration of copper and then perform the phalloidin staining.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.