Specifications
Absorbance Accuracy3% (at 0.74 Abs at 350 nm)
Absorbance Range0 to 75 A
Certifications/ComplianceUL/CSA and CE
CompatibilityProfessional versions of Microsoft™ Windows™ 7 (32 bit and 64 bit), Windows Vista (32 bit), and Windows XP (32 bit).
ConnectionsUSB
Depth (Metric)32 cm
Detection Limits2.5 ng/μL (dsDNA)
Detection Range2.5 to 3,700 ng/μL (dsDNA), 0.15 to 100 mg/mL (BSA)
Detector Type2048-element Linear Silicon CCD Array
Light SourceXenon Flash
TypeMicrovolume Spectrometer with Laptop
Voltage12 VDC
Wavelength Range220 to 750 nm
Footprint24 x 32 cm
For Use With (Application)Nucleic acid, protein, cell culture and custom methods
Measurement Time<20 sec.
No. of Samples8
Pathlength0.2 and 1.0 mm
Power Consumption30 W
Sample Volume (Metric)1 μL
Spectral Resolution≤3 nm (FWHM at Hg 546.1 nm)
System RequirementsMicrosoft Windows 7 Professional (32-bit and 64-bit), Windows 8 (32- and 64-bit), and Windows 10 Pro (64-bit)
Warranty1 year parts and labor
Wavelength Accuracy±1 nm
Unit SizeEach