Reduce helium consumption or migrate to a more readily available gas for your GC-MS analysis. Either way, the Thermo Scientific HeSaver-H2Safer injector helps reduce costs while achieving your analytical goals. HeSaver-H2Safer technology results in 72% percent gas savings and a 3.5x extension of cylinder lifetime in standard conditions.

Need to reduce Helium consumption?

Need to reduce your Helium gas consumption?

Learn how you can reduce helium consumption and analysis costs

Extend your Helium cylinder lifetime from months to years with the HeSaver-H2Safer that replaces purge and split flow with Nitrogen.

Whether you use helium or hydrogen, you can better manage carrier gas consumption with HeSaver-H2Safer technology.

 

Hear how this high-throughput lab deals with the helium shortage, without switching carrier gas.

 

Ready to migrate to Hydrogen as your carrier gas?

Ready to migrate to Hydrogen as your carrier gas?

Discover the benefits of migrating to carrier gas hydrogen

The HeSaver-H2Safer makes it safer to use hydrogen with no hydrogen discharge in the ambient and no need for a hydrogen sensor.

Free HeSaver-H2Safer

Maximize uptime and save money with a new modular GC-MS or GC-MS/MS. Ensure that your lab can adapt and grow, even when experiencing volatility and rising costs. Take advantage of exclusive promotions and extended warranties — Get ready for what’s next by lining your bench with the latest advancements in GC instrumentation.

Upgrade your SSL injector to HeSaver-H2Safer free of charge with new GC-MS or GC-MS/MS. This limited time offers enable your laboratory to remain at the forefront of analytical capability while reducing costs through reduced carrier gas consumption. This offer can be combined with extended warranty and trade-in discounts. 

Benefits include:

Smart

Smart. Limits carrier gas consumption during analysis and switches off the gas when the GC is idle.

Easy

Easy. The self installable kit makes it easy to upgrade your standard IConnect SSL with TRACE 1600 Series GC.

Flexible

Flexible. Benefit from limited carrier gas consumption, whether you use Helium or Hydrogen.


Financing

Eliminate budgetary constraints on essential equipment purchases

Eliminate budgetary constraints on essential equipment purchases

Power up your lab with flexible financing and pay at your own rate. Get the equipment your laboratory needs with a range of financial solutions and leasing services- from deferred payment plans to leasing options or interest-free financing. Our financing experts can provide a customized payment plan that fits your unique budgetary needs.

  • No-Interest Program — Up to 12 months of interest-free financing.
  • Extended Terms Agreement — Spread out the cost of new instruments by adding up to nine months to your payment window.
  • All-Inclusive Lease Program One convenient monthly payment for equipment, consumables, service agreements and financing.

Learn more about reducing helium consumption or migrating to a more readily available gas

The Thermo Scientific HeSaver-H2Safer kit for the Thermo Scientific iConnect SSL injector module is a unique patented technology that saves helium gas around-the-clock. It uses Helium (or Hydrogen) carrier gas only to feed the analytical column (a few mL/min) and uses Nitrogen for splitting the sample, which is the primary source of gas consumption.

The energy savings with the HeSaver SSL technology depends on the method used and the split flow used in the method. In standard conditions, the HeSaver-H2Safer technology results in 72% percent gas savings and a 3.5x extension of cylinder lifetime.

The Thermo Scientific HeSaver-H2Safer technology for SSL significantly reduces carrier gas consumption. Any iConnect Split/Splitless (SSL) injector module mounted on a Trace 1600 GC-MS can be easily upgraded with a self-installable kit to be used as a HeSaver-H2Safer injector. This technology helps to significantly reduce the total carrier gas consumption of both Helium and Hydrogen (depending on which carrier gas is used in your method). Essentially, you’ll use the valuable carrier gas only to feed the column while using a cheaper gas for maintaining the septum purge and split flow, which represents the majority of gas consumption.

Helium saver technology does not impact sensitivity in any way. The acceptance criteria for Dioxin analysis include: quantification and confirmation ions that must be within .001 min retention time tolerance; ion ratios that must be within 15%; and the average relative response time that must be within 20%. All these criteria were met with the Helium saver technology.

Carrier gas separates and analyzes quickly while preserving the sample integrity. For standalone gas chromatographs, Hydrogen is the most recommended option for replacing Helium because it offers very high efficiency in a short period of time.

Hydrogen is a very powerful, less expensive carrier gas than helium. It’s also renewable and readily available to laboratories since it can be generated on site using a hydrogen generator. From a chromatography perspective, it has low viscosity and high diffusivity offering high separation efficiency in a shorter analysis time. It’s an ideal gas to be combined with short and narrow bore columns. Hydrogen is compatible with FID and other conventional detectors. When Hydrogen is used with the HeSaver-H2Safer technology, it can eliminate safety risks (even in cases of high split ratio), as well as possible side reactions into the hot injector.

HeSaver-H2Safer technology eliminates safety risk due to possible accumulation of Hydrogen into the GC oven. Since the maximum flow rate is limited, there’s no chance for the carrier gas to reach hazardous concentrations—even in the event of column breakage. Also, no Hydrogen is discharged into the ambient air through the split or purge lines, and there’s no interaction with the sample into the hot injector.

When we use the Helium saver versus the regular split/splitless, we save 7.5 times the amount of helium. Assuming your lab is doing 24/7 analysis for the entire year, the Helium cylinder will last for 1.8 years, compared to 3 months with the regular split/splitless method. This is a considerable resource and cost savings.