Search
Search
Our workflows and solutions are purpose-built for reliable, accurate detection of organic and emerging contaminants, including per-fluoroalkyl substances (PFAS) and pesticides. In combination with our validation-ready methods, these workflows make environmental analysis and food testing more accessible and efficient than ever before. Choose one of our intelligent sample preparation options and combine it with our recommended hardware and software configurations into a workflow that will not only meet your needs today, but offers the scalability to keep you ready for what’s next.
Regulated analyses of both environmental and food samples require traceable, defensible results for targeted quantitation. Our seamless workflows feature automated sample preparation, which reduces the variability inherent in manual sample preparation, reliable liquid chromatography systems, familiar, powerful mass spectrometry and software that seamlessly integrates instrument control, data acquisition, processing, quantitation, and compliant reporting. Together, these instruments create a streamlined, end-to-end solution that empowers laboratories to confidently meet evolving regulatory requirements and deliver accurate results from sample to report.
For food and environmental labs, this workflow features automated dispersive liquid-liquid micro extraction (DLLME) sample preparation, using the Thermo Scientific TriPlus RSH SMART autosampler. It includes robust chromatographic separation using the Thermo Scientific Vanquish Duo UHPLC system, paired with our familiar and trusted Thermo Scientific TSQ Altis Plus EFOX Edition Triple Quadrupole Mass Spectrometer and Thermo Scientific Chromeleon software, which unifies instrument and data control. This integrated workflow offers excellent quantitative performance for regulated labs.
For analysis of organic contaminants, including PFAS and pesticides, this workflow supports regulatory-compliant targeted quantitation of both environmental and food samples in routine labs with minimal method development required. Like the DLLME-EFOX Edition triple-quadrupole LC-MS workflow, it uses the DLLME sample preparation technique but also enables full-scan HRAM detection and retrospective analysis for evolving contaminant lists by employing LC-MS featuring our high-resolution accurate mass (HRAM) Thermo Scientific Orbitrap Exploris EFOX Mass Detector. This workflow keeps your lab future-ready by maintaining the scalability required for emerging contaminant compounds.
For environmental testing, this workflow uses solid-phase extraction for automated sample preparation with the Thermo Scientific Dionex AutoTrace 280 Solid Phase Extraction (SPE) system. This sample preparation system provides fully automated SPE for consistent extraction and concentration of trace contaminants from matrices, enhancing reproducibility while minimizing hands-on time and solvent usage. Like the DLLME-EFOX Edition triple-quadrupole LC-MS workflow, it uses the Vanquish Duo UHPLC system and the TSQ Altis Plus EFOX Edition Mass Spectrometer for a streamlined, end-to-end solution that empowers laboratories to confidently meet evolving regulatory requirements and deliver accurate results from sample to report.
Our solid-matrix workflow for complex environmental and food testing uses accelerated solvent extraction, using the Thermo Scientific EXTREVA ASE Accelerated Solvent Extractor for sample preparation. The EXTREVA ASE system ensures efficient recovery of analytes from demanding samples such as soil, sediment, feed, and processed foods, supporting consistent preparation and reduced manual handling. In combination with the Vanquish Duo UHPLC system, the TSQ Altis Plus EFOX Edition Triple Quadrupole Mass Spectrometer and Chromeleon software, this workflow delivers high-performance, regulation-focused analysis.
Our General Purpose product-lines are not intended for in vitro diagnostic purposes in accordance with our product documentation, manuals, and labels. They are designated for General Laboratory Use Only.
Our Products have not been tested or validated for such applications and their use for in vitro diagnostic purposes may result in inaccurate results and, more seriously, health and safety risks.
For General Lab Use Only - Not For Diagnostic Procedures.