Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES)

Analyze the most challenging samples

The Thermo Scientific iCAP PRO Series ICP-OES combines powerful multi-element capability with flexibility, so your lab is ready for any challenge. Produce consistent, reliable data quickly and easily. Experience enhanced sample throughput, matrix tolerance, and flexibility to produce results you can trust.

Contact Us

ICP-OES analyzers

Deliver robust, uncomplicated trace elemental analysis for your laboratory with the Thermo Scientific iCAP PRO ICP-OES and Thermo Scientific iCAP PRO X ICP-OES systems. These systems offer easy-to-use software and provide multi-element detection technology far superior to that of single-element AAS and multi element microwave plasma techniques. These instruments are ideal for laboratories with low sample throughput requirements. For ease of use a number of optimized settings are defined as standard, making them ideal for users new to the technique or those who require a simple solution for multi elemental analysis.

Analyze high-matrix trace elemental samples with sensitive multi-element detection and meet your data requirements with the optimal performance of the Thermo Scientific iCAP PRO XP ICP-OES. Rugged on all fronts, this system needs surprisingly little bench space or user maintenance. The instrument achieves an advanced level of performance with either the iFR analysis mode which measures the entire wavelength range in one measurement, or the eUV analysis mode which measures the UV region of the spectrum with greater sensitivity.

Analyze elemental samples in the shortest possible time with the Thermo Scientific iCAP PRO XPS ICP-OES. The high light throughput optics combined with the charge injection device detector, the CID821, ensure the shortest possible analysis times. When using the iFR analysis mode, the complete spectrum is captured in one measurement, further reducing analysis times. For the most demanding applications that require the highest sensitivity in the UV region of the spectrum to determine elements such as mercury, antinomy and lead the eUV analysis mode enhances the sensitivity, ensuring regulations for toxic elements are easily met.


ICP-OES technique selector

  iCAP PRO
ICP-OES
iCAP PRO X
ICP-OES
iCAP PRO XP
ICP-OES
iCAP PRO XPS
ICP-OES
Plasma view Vertical Radial or Vertical Duo
Start up time 1 hour (from off) 15 minutes
(from standby)
5 minutes (from standby)
Wavelength range iFR mode 167.021 nm - 852.145 nm iFR mode 167.021 nm - 852.145 nm

eUV mode 167.021 nm - 240.063 nm
Resolution @ 200nm 7 pm
Measurement modes iFR iFR and eUV
Camera technology CID821
Full spectrum capture Yes
RF source radial 1150 W 750, 1150
or 1350 W
750 to 1600 W
RF source duo 1150 W 750, 1150
or 1350 W
750 to 1600 W
Gas flow controls Optimized MFC Variable MFC
Plasma gas Fixed at 12.5 L/min Fixed, optimized at
8.5, 12.5 or 14.5 L/min
0 to 20 L/min
Auxiliary gas Fixed at 0.5 L/min Selectable
0.5, 1 or 1.5 L/min
0 to 2 L/min
Nebulizer gas 0.3 to 0.8 L/min 0 to 1.5 L/min 0.0 to 1.5 L/min
Additional gas 0 - 0.25 L/min

iCAP PRO Series ICP-OES videos

Get a look inside the iCAP PRO Series ICP-OES

Take a flight through the iCAP PRO Series ICP-OES optics and get a close-up view of its plasma, light separation and detection features.

 

Advanced elemental analysis

Analysis of used lubrication oils

Screening analysis of soils

Analysis of complex matrices using ICP-OES at DOW


CMD SchemaApp code