Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES)

Analyze the most challenging samples

The Thermo Scientific iCAP PRO Series ICP-OES combines powerful multi-element capability with flexibility, so your lab is ready for any challenge. Produce consistent, reliable data quickly and easily. Experience enhanced sample throughput, matrix tolerance, and flexibility to produce results you can trust.

Contact Us

ICP-OES analyzers

Deliver robust, uncomplicated trace elemental analysis for your laboratory with the Thermo Scientific iCAP PRO ICP-OES and Thermo Scientific iCAP PRO X ICP-OES systems. These systems offer easy-to-use software and provide multi-element detection technology far superior to that of single-element AAS and multi element microwave plasma techniques. These instruments are ideal for laboratories with low sample throughput requirements. For ease of use a number of optimized settings are defined as standard, making them ideal for users new to the technique or those who require a simple solution for multi elemental analysis.

Analyze high-matrix trace elemental samples with sensitive multi-element detection and meet your data requirements with the optimal performance of the Thermo Scientific iCAP PRO XP ICP-OES. Rugged on all fronts, this system needs surprisingly little bench space or user maintenance. The instrument achieves an advanced level of performance with either the iFR analysis mode which measures the entire wavelength range in one measurement, or the eUV analysis mode which measures the UV region of the spectrum with greater sensitivity.

Analyze elemental samples in the shortest possible time with the Thermo Scientific iCAP PRO XPS ICP-OES. The high light throughput optics combined with the charge injection device detector, the CID821, ensure the shortest possible analysis times. When using the iFR analysis mode, the complete spectrum is captured in one measurement, further reducing analysis times. For the most demanding applications that require the highest sensitivity in the UV region of the spectrum to determine elements such as mercury, antinomy and lead the eUV analysis mode enhances the sensitivity, ensuring regulations for toxic elements are easily met.


ICP-OES technique selector

 iCAP PRO
ICP-OES
iCAP PRO X
ICP-OES
iCAP PRO XP
ICP-OES
iCAP PRO XPS
ICP-OES
Plasma viewVertical Radial or Vertical Duo
Start up time1 hour (from off)15 minutes
(from standby)
5 minutes (from standby)
Wavelength rangeiFR mode 167.021 nm - 852.145 nmiFR mode 167.021 nm - 852.145 nm

eUV mode 167.021 nm - 240.063 nm
Resolution @ 200nm7 pm
Measurement modesiFRiFR and eUV
Camera technologyCID821
Full spectrum captureYes
RF source radial1150 W750, 1150
or 1350 W
750 to 1600 W
RF source duo1150 W750, 1150
or 1350 W
750 to 1600 W
Gas flow controlsOptimized MFCVariable MFC
Plasma gasFixed at 12.5 L/minFixed, optimized at
8.5, 12.5 or 14.5 L/min
0 to 20 L/min
Auxiliary gasFixed at 0.5 L/minSelectable
0.5, 1 or 1.5 L/min
0 to 2 L/min
Nebulizer gas0.3 to 0.8 L/min0 to 1.5 L/min0.0 to 1.5 L/min
Additional gas0 - 0.25 L/min