Zeba desalting columns and plates size-exclusion chromatography products are used in research applications that involve the separation of proteins, and other macromolecules from soluble low molecular weight substances (e.g., salts) that may adversely impact the stability of the analytes or interfere with downstream applications. Zeba desalting products are also used in protein buffer exchange to more appropriate buffers before subsequent applications such as western blotting, immunoprecipitation, activity assays, and mass spectrometry.


Desalting format selection guide

Formatgloved hand holding a Zeba desalting spin column
Desalting Spin Columns
gloved hand holding a stack of Zeba desalting spin plates
Desalting Spin Plates
gloved hand holding a Zeba desalting chromatography cartridge
Desalting Chromatography Cartridges
Sample volume range2 μL–10 mL20–100 μL15–250 μL
Resin bed volume75 μL–20 mL550 μL1 mL–5 mL
Resin molecular weight cut-off (MWCO)7 kDa, 40 kDa7 kDa, 40 kDa7 kDa
Automation-compatible?NoYesYes
Products7K
40K
2 96-well filter plates
4 96-well filter plates
1 column x 5 mL
5 columns x 1 mL

Desalting Spin Columns

Thermo Scientific Zeba Spin Desalting Columns are made of low protein-binding polypropylene and are compatible with a wide range of standard laboratory instruments and consumables.

Our Zeba columns are designed for use with most swinging-bucket or fixed-angle bench- or floor-model centrifuges (please verify head clearance before use) and are available in six volume capacities and two molecular weight cut-offs (MWCOs), 7K and 40K.

The MWCO should be lower than the molecular weight of the target molecule to help ensure it is retained while contaminants are reduced. Columns with 7K help provide finer resolution for smaller molecules, useful for purifying smaller proteins (e.g., cytochrome c) or peptides (e.g., insulin). Columns with 40K are better suited for large proteins (e.g., BSA), protein complexes (e.g., hemoglobin) and large enzymes (e.g,. pyruvate kinase).

Size exclusion desalting spin column with 7K MWCO selection guide

 : Zeba Micro Spin Column, 7K: Zeba 0.5 mL Desalting Spin Column, 7KZeba 2 mL Desalting Spin Column, 7KZeba 5 mL Desalting Spin Column, 7KZeba 10 mL Desalting Spin Column, 7KZeba 20 mL Desalting Spin Column, 7K
Sample volume2–12 µL30–130 µL200–700 µL500–2,000 µL700–4,000 µL4,000–10,000 µL
Resin bed volume75 μL0.5 mL2 mL5 mL10 mL20 mL
Product typeMicro Spin Column0.5 mL Spin Column2 mL Spin Column5 mL Spin Column10 mL Spin Column20 mL Spin Column

Size exclusion desalting spin column with 40K MWCO selection guide

 : Zeba Micro Spin Column, 40K: Zeba 0.5 mL Desalting Spin Column, 40KZeba 2 mL Desalting Spin Column, 40KZeba 5 mL Desalting Spin Column, 40KZeba 10 mL Desalting Spin Column, 40KZeba 20 mL Desalting Spin Column, 40K
Sample volume5–14 µL70–200 µL200–900 µL300–2,000 µL1000–4,000 µL4,000–10,000 µL
Resin bed volume75 μL0.5 mL2 mL5 mL10 mL20 mL
Product typeMicro Spin Column0.5 mL Spin Column2 mL Spin Column5 mL Spin Column10 mL Spin Column20 mL Spin Column

Additional products used to efficiently wash away contaminants and elute your purified sample:

Spin desalting plates and cartridges for high throughput and automation

 Zeba 96-Well Desalting Filter Plate, 7KZeba 96-Well Desalting Filter Plate, 40K1 mL Desalting Cartridges, 7KZeba 5 mL Desalting Cartridges, 7K
MWCO7K40K7K7K
Sample volume20–100 µL20–100 µL50–250 µL100–1,500 µL
Resin bed volumeN/AN/A1 mL5 mL
Product type96-well filter plates96-well filter plates1 mL Desalting Cartridges5 mL Desalting Cartridges
Desalting Spin Columns

Thermo Scientific Zeba Spin Desalting Columns are made of low protein-binding polypropylene and are compatible with a wide range of standard laboratory instruments and consumables.

Our Zeba columns are designed for use with most swinging-bucket or fixed-angle bench- or floor-model centrifuges (please verify head clearance before use) and are available in six volume capacities and two molecular weight cut-offs (MWCOs), 7K and 40K.

The MWCO should be lower than the molecular weight of the target molecule to help ensure it is retained while contaminants are reduced. Columns with 7K help provide finer resolution for smaller molecules, useful for purifying smaller proteins (e.g., cytochrome c) or peptides (e.g., insulin). Columns with 40K are better suited for large proteins (e.g., BSA), protein complexes (e.g., hemoglobin) and large enzymes (e.g,. pyruvate kinase).

Size exclusion desalting spin column with 7K MWCO selection guide

 : Zeba Micro Spin Column, 7K: Zeba 0.5 mL Desalting Spin Column, 7KZeba 2 mL Desalting Spin Column, 7KZeba 5 mL Desalting Spin Column, 7KZeba 10 mL Desalting Spin Column, 7KZeba 20 mL Desalting Spin Column, 7K
Sample volume2–12 µL30–130 µL200–700 µL500–2,000 µL700–4,000 µL4,000–10,000 µL
Resin bed volume75 μL0.5 mL2 mL5 mL10 mL20 mL
Product typeMicro Spin Column0.5 mL Spin Column2 mL Spin Column5 mL Spin Column10 mL Spin Column20 mL Spin Column

Size exclusion desalting spin column with 40K MWCO selection guide

 : Zeba Micro Spin Column, 40K: Zeba 0.5 mL Desalting Spin Column, 40KZeba 2 mL Desalting Spin Column, 40KZeba 5 mL Desalting Spin Column, 40KZeba 10 mL Desalting Spin Column, 40KZeba 20 mL Desalting Spin Column, 40K
Sample volume5–14 µL70–200 µL200–900 µL300–2,000 µL1000–4,000 µL4,000–10,000 µL
Resin bed volume75 μL0.5 mL2 mL5 mL10 mL20 mL
Product typeMicro Spin Column0.5 mL Spin Column2 mL Spin Column5 mL Spin Column10 mL Spin Column20 mL Spin Column

Additional products used to efficiently wash away contaminants and elute your purified sample:

Spin desalting plates and cartridges for high throughput and automation

 Zeba 96-Well Desalting Filter Plate, 7KZeba 96-Well Desalting Filter Plate, 40K1 mL Desalting Cartridges, 7KZeba 5 mL Desalting Cartridges, 7K
MWCO7K40K7K7K
Sample volume20–100 µL20–100 µL50–250 µL100–1,500 µL
Resin bed volumeN/AN/A1 mL5 mL
Product type96-well filter plates96-well filter plates1 mL Desalting Cartridges5 mL Desalting Cartridges

Zeba desalting column product performance

Zeba Spin Desalting Columns are designed to provide exceptional desalting and buffer exchange capabilities for quality results in your protein purification workflows. These columns utilize a resin technology that allows for efficient separation of salts and small molecules from proteins, offering high recovery rates and fast processing times. With their user-friendly spin format, Zeba columns facilitate quick and convenient sample processing while maintaining protein integrity and activity. Explore our performance data below.

Volume capacity

Zeba Spin Desalting Columns are available in a variety of sizes and volume capacities compared to competitor offerings (Figure 1). Zeba columns can also be used with volumes as small as 5 µL (in micro format) to as large as 10 mL.

Protein recovery

Zeba 40K Spin Desalting Columns contain an enhanced high-performance size-exclusion chromatography resin. These redeveloped Zeba columns demonstrate improved protein recovery for a variety of proteins in the 40 kDa and above molecular weight range (Table 1).

Table 1. Protein recovery comparison using Zeba Protein Desalting Columns with 7K and 40K MWCO resin.

 Recovery*
ProteinMolecular Size7K Zeba Column40K Zeba Column
Bacitracin1.5 kDa15%12%
Aprotinin6.5 kDa58%37%
Ubiquitin8.5 kDa78%51%
Lactalbumin14 kDa88%64%
Trypsin Inhibitor21 kDa94%76%
Carbonic Anhydrase30 kDa90%79%
Ovalbumin42 kDa95%95%
BSA67 kDa94%93%
Rabbit IgG150 kDa92%92%

*Recovery of 100 uL sample volume, with a loaded concentration of 0.5 mg/mL.

Zeba 7K Spin Desalting Columns contain a high-performance size-exclusion chromatography resin that allows for exceptional protein desalting and recovery. When compared to competitors, Zeba 7K desalting columns have excellent protein recovery even at dilute protein concentrations (Figure 2).

Zeba 40K Spin Desalting Columns provide exceptional performance that improves protein recovery compared to competitors (Figure 3). Further, the resin in the Zeba 40K desalting columns allows for higher desalting and is more effective at small protein removal (Figure 4).

Figure 3. Exceptional sample recovery of low protein loads with Zeba 40K spin columns. BSA and IgG of varying concentrations were applied in 50µL aliquots to either 0.5 mL Zeba 40K, competitor C, or Competitor B spin columns. All columns were equilibrated with PBS, then centrifuged per manufacturers’ instructions for each resin. Recovered protein (%) in each flow through sample was determined by BCA assay. Flow through samples were performed on SDS-PAGE and stained with either Coomassie Blue or silver stain. Although 12.5 µg total protein load was recovered efficiently by all three resins, lower recoveries were observed with competitor resins at 1 ug and 250 ng protein loads.

Figure 4. Enhanced Zeba 40K resin is effective at removing small proteins. Purified protein samples (0.5mg/mL) of varying molecular weights were applied individually in 50 µL aliquots in either 0.5 mL Zeba 40K, Competitor C, or Competitor B spin columns equilibrated in PBS. Columns were centrifuged per manufacturers’ instructions for each resin, and the recovered protein (%) in each flow-through sample was determined by BCA protein assay. As opposed to competitor columns, the Zeba 40K resin was more efficient at reducing smaller proteins (evidenced by the lower small protein recovery values).


Desalting resources

Video: Sample desalting using gel filtration chromatography

Watch the video to see how Zeba desalting products work by using gel filtration chromatography.

Video: Zeba Spin Desalting Columns and Plates

Watch the video to learn how to desalt your sample using the Zeba Spin Desalting Columns.

Technical documents

For Research Use Only. Not for use in diagnostic procedures.