Search
Search

Dialysis Cassettes, Flasks, & Devices |
Dialysis cassettes are a secure alternative to traditional dialysis tubing and designed to be convenient. The Slide-A-Lyzer G3 dialysis cassette offers a rigid-framed, free-standing, and self-floating vessel with a secure cap closure and large surface area consisting of regenerated cellulose membranes for simple and efficient dialysis experiments. Samples can be loaded and retrieved easily using a serological pipette.
In contrast, traditional dialysis membrane tubing presents a number of challenges: the tubing bag is slippery when wet and requires knots or plastic clips to secure the sample. Leakage or contamination of the sample is likely because the membrane must be closed manually (see comparison table).
| Mini Dialysis Device (Dialysis Cups) | G3 Dialysis Cassettes | Dialysis Flasks | |
|---|---|---|---|
| Volume range | 10 μL–2 mL | 1–125 mL | 150–250 mL |
| External float required | Yes (0.1 mL size only) | No | Yes |
| Sample removal | Pipette | Pipette | Pipette, directly pouring |
| Molecular weight cutoffs (MWCOs) | 2K (0.1 mL size only), 3.5K, 10K, 20K | 2K, 3.5K, 10K, 20K | 2K, 3.5K, 10K, 20K |
Click on the tabs below to explore dialysis devices, including cups, cassettes, and flasks.
Slide-A-Lyzer MINI dialysis devices have a cup-like design that is available in 3 volume sizes: 0.1 mL devices, which can be placed into a foam float during dialysis, and 0.5 mL and 2 mL sizes, which are capped by inserting them into the included 15 mL and 50 mL conical tubes, respectively. The tubes serve as dialysis reservoirs for easy and self-contained dialysis and are available in 2K, 3.5K, 7K, 10K, and 20K MWCOs.
Use the Slide-A-Lyzer MINI Dialysis Devices in applications including low molecular weight contaminant removal, buffer exchange, desalting, equilibrium dialysis, microconjugation reactions, and sample concentration.
Additional features of Slide-A-Lyzer MINI dialysis devices:
The Slide-A-Lyzer MINI device makes dialyzing small volumes easy. Just add the sample, place the device in the conical tube (for 0.5 mL and 2 mL devices), recap, and shake for up to 4 hours or overnight. Use a pipet to recover the sample (Figure 1).
Figure 1. Slide-A-Lyzer MINI dialysis device workflow.
| Membrane MWCO | Protein/Peptide | Recovery (%) |
|---|---|---|
| 3.5K | Insulin Chain B (3.5 kDa) | 90.13 |
| 10K | Cytochrome C (12.4 kDa) | 94.44 |
| 20K | Myoglobin (17 kDa) | 95 |
Insulin chain B, cytochrome C and myoglobin (0.25 mg/mL) in either 50 mM sodium phosphate, 75 mM NaCl at pH 7.2 or 0.2 M carbonate-bicarbonate buffer at pH 9.4 were dialyzed overnight (17 hours) at 4°C. The amount of protein in the retentate was determined using the Pierce BCA Protein Assay.
Slide-A-Lyzer G3 dialysis cassettes accommodate volumes ranging from 1–125 mL, and are available in 2K, 3.5K, 10K, and 20K molecular weight cutoffs (MWCOs).
Use Slide-A-Lyzer G3 dialysis cassettes in various applications, including low molecular-weight contaminant and salt removal, buffer exchange, and sample concentration.
Additional features of the Slide-A-Lyzer G3 dialysis cassettes:
The Slide-A-Lyzer G3 dialysis cassette is simple to use. Load the cassette with sample, put it into the dialysis buffer, and then retrieve the sample (Figure 2).
Figure 2. Slide-A-Lyzer G3 dialysis cassettes workflow.
![]() | ![]() | |
|---|---|---|
| Dialysis product | Traditional tubing | Cassette |
| Sample handling | Slippery when wet Flat tubing is difficult to handle when wet, increasing risk of sample loss during sample addition/removal | Easy handling and secure sample delivery Plastic frame and cap allow for secure sample addition/removal |
| Sample recovery | Risk of sample loss Sample can leak out if clamp becomes loose or falls off | Sample protection Welded membrane and leak-proof cap helps reduce the risk of sample loss |
| Speed | Time consuming Non-optimized design that typically requires overnight dialysis | Fast and efficient Innovative design with high surface/volume ratio allows for more rapid dialysis than conventional tubing |
Slide-A-Lyzer dialysis flasks facilitate simple and effective dialysis in larger sample volumes ranging from 150 mL up to 250 mL. These devices accomplish typical buffer exchange in 8–24 hours and are available in 2K, 3.5K, 10K, and 20K MWCOs. The dialysis flasks are available in distinct colors that correspond to the MWCO of the dialysis membrane: purple (20 kDa), orange (10 kDa), pink (3.5 kDa), and blue (2 kDa).
Use Slide-A-Lyzer dialysis flasks in various applications, including low molecular-weight contaminant and salt removal, buffer exchange, and sample concentration.
Additional features of Slide-A-Lyzer dialysis flasks:
| MWCO | Volume | Description |
|---|---|---|
| 2K | 250 mL | Slide-A-Lyzer Dialysis Flasks, blue |
| 3.5K | 250 mL | Slide-A-Lyzer Dialysis Flasks, pink |
| 10K | 250 mL | Slide-A-Lyzer Dialysis Flasks, orange |
| 20K | 250 mL | Slide-A-Lyzer Dialysis Flasks, purple |
Slide-A-Lyzer Dialysis flasks make sample loading and recovery easy. Simply attach the supplied float-ring and hydrate membrane for 2 minutes, pour sample into device, remove air, and replace the cap. Dialyze for 8 hours to overnight. Replace buffer after 2 and 5 hours, then pour out sample to recover (Figure 3).
Figure 3. Slide-A-Lyzer dialysis flasks workflow.
Slide-A-Lyzer MINI dialysis devices have a cup-like design that is available in 3 volume sizes: 0.1 mL devices, which can be placed into a foam float during dialysis, and 0.5 mL and 2 mL sizes, which are capped by inserting them into the included 15 mL and 50 mL conical tubes, respectively. The tubes serve as dialysis reservoirs for easy and self-contained dialysis and are available in 2K, 3.5K, 7K, 10K, and 20K MWCOs.
Use the Slide-A-Lyzer MINI Dialysis Devices in applications including low molecular weight contaminant removal, buffer exchange, desalting, equilibrium dialysis, microconjugation reactions, and sample concentration.
Additional features of Slide-A-Lyzer MINI dialysis devices:
The Slide-A-Lyzer MINI device makes dialyzing small volumes easy. Just add the sample, place the device in the conical tube (for 0.5 mL and 2 mL devices), recap, and shake for up to 4 hours or overnight. Use a pipet to recover the sample (Figure 1).
Figure 1. Slide-A-Lyzer MINI dialysis device workflow.
| Membrane MWCO | Protein/Peptide | Recovery (%) |
|---|---|---|
| 3.5K | Insulin Chain B (3.5 kDa) | 90.13 |
| 10K | Cytochrome C (12.4 kDa) | 94.44 |
| 20K | Myoglobin (17 kDa) | 95 |
Insulin chain B, cytochrome C and myoglobin (0.25 mg/mL) in either 50 mM sodium phosphate, 75 mM NaCl at pH 7.2 or 0.2 M carbonate-bicarbonate buffer at pH 9.4 were dialyzed overnight (17 hours) at 4°C. The amount of protein in the retentate was determined using the Pierce BCA Protein Assay.
Slide-A-Lyzer G3 dialysis cassettes accommodate volumes ranging from 1–125 mL, and are available in 2K, 3.5K, 10K, and 20K molecular weight cutoffs (MWCOs).
Use Slide-A-Lyzer G3 dialysis cassettes in various applications, including low molecular-weight contaminant and salt removal, buffer exchange, and sample concentration.
Additional features of the Slide-A-Lyzer G3 dialysis cassettes:
The Slide-A-Lyzer G3 dialysis cassette is simple to use. Load the cassette with sample, put it into the dialysis buffer, and then retrieve the sample (Figure 2).
Figure 2. Slide-A-Lyzer G3 dialysis cassettes workflow.
![]() | ![]() | |
|---|---|---|
| Dialysis product | Traditional tubing | Cassette |
| Sample handling | Slippery when wet Flat tubing is difficult to handle when wet, increasing risk of sample loss during sample addition/removal | Easy handling and secure sample delivery Plastic frame and cap allow for secure sample addition/removal |
| Sample recovery | Risk of sample loss Sample can leak out if clamp becomes loose or falls off | Sample protection Welded membrane and leak-proof cap helps reduce the risk of sample loss |
| Speed | Time consuming Non-optimized design that typically requires overnight dialysis | Fast and efficient Innovative design with high surface/volume ratio allows for more rapid dialysis than conventional tubing |
Slide-A-Lyzer dialysis flasks facilitate simple and effective dialysis in larger sample volumes ranging from 150 mL up to 250 mL. These devices accomplish typical buffer exchange in 8–24 hours and are available in 2K, 3.5K, 10K, and 20K MWCOs. The dialysis flasks are available in distinct colors that correspond to the MWCO of the dialysis membrane: purple (20 kDa), orange (10 kDa), pink (3.5 kDa), and blue (2 kDa).
Use Slide-A-Lyzer dialysis flasks in various applications, including low molecular-weight contaminant and salt removal, buffer exchange, and sample concentration.
Additional features of Slide-A-Lyzer dialysis flasks:
| MWCO | Volume | Description |
|---|---|---|
| 2K | 250 mL | Slide-A-Lyzer Dialysis Flasks, blue |
| 3.5K | 250 mL | Slide-A-Lyzer Dialysis Flasks, pink |
| 10K | 250 mL | Slide-A-Lyzer Dialysis Flasks, orange |
| 20K | 250 mL | Slide-A-Lyzer Dialysis Flasks, purple |
Slide-A-Lyzer Dialysis flasks make sample loading and recovery easy. Simply attach the supplied float-ring and hydrate membrane for 2 minutes, pour sample into device, remove air, and replace the cap. Dialyze for 8 hours to overnight. Replace buffer after 2 and 5 hours, then pour out sample to recover (Figure 3).
Figure 3. Slide-A-Lyzer dialysis flasks workflow.
For Research Use Only. Not for use in diagnostic procedures.